PWR-C5-1KWAC/2 – 1000W AC power supply for Catalyst 9200

(11 customer reviews)
Questions

0/mo Solds

List Price: $2632 $743.22
  • 100% Genuine
    Original, factory-authenticated
  • S/N Verifiable
    Verified by official serial-check
Condition New Factory Sealed Related Quantity
Trusted & Secure Payments
Shipping Express Shipping 2-6 Days, via DHL, FedEx, UPS, etc. Packaging weight and dimensions included:

Stable Global Supply Chain for Thriving Businesses.

  • $3,000,000 Inventory
  • Certified Cisco Partner ships
  • Collaborating with FedEx, UPS, DHL

Free Expert Support from Planning to Deployment

  • Assistance with product selection and network solution design
  • Configuration guidance and best-practice recommendations
  • Troubleshooting support provided by CCIE-level technical experts

Established Global IT Distributor

With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.

PWR-C5-1KWAC/2 Description

The PWR-C5-1KWAC/2 is a hot-swappable, secondary 1 kW AC power supply designed for Cisco Catalyst 9200 Series switches. Often called the secondary AC redundant PSU or 1 kW AC backup power module, it provides seamless failover in mission-critical branch and campus deployments. With universal 100–240 VAC input and 54 VDC/16.5 A output, it delivers stable power under heavy PoE+ loads and features a 20 ms holdup time to prevent interruptions during brief outages. Engineered for drop-in redundancy alongside the primary PWR-C5-1KWAC, this module ensures up to 1.44 kW of combined PoE capacity when installed as a pair—maximizing uptime and simplifying maintenance in high-availability networks.

Model Meaning

Field

Meaning

PWR

Power Supply

C5

Config 5 for Cisco Catalyst 9200 Series

1KW

1 000 W maximum output power

AC

Alternating-current input

/2

Secondary (redundant) power supply

Supported Platforms

    Model comparison

    Parameter

    PWR-C5-600WAC/2

    PWR-C5-1KWAC/2

    Rated Power

    600 W

    1000 W

    Input Voltage Range

    100 – 240 VAC, 50 – 60 Hz

    100 – 240 VAC, 50 – 60 Hz

    Input Current

    7 – 2.8 A

    12 – 6 A

    Output Voltage

    54 VDC

    54 VDC

    Output Current

    11.1 A

    16.5 A

    Holdup Time

    ≥ 20 ms at 100 VAC

    ≥ 20 ms at 100 VAC

    Total Output BTU/hr

    2047.3 BTU/hr

    3412 BTU/hr

    Dimensions (H × W × D)

    1.58″ × 4.0″ × 7.6″

    1.58″ × 4.0″ × 7.6″

    Weight

    1.7 lb (0.77 kg)

    2 lb (0.9 kg)

    Connector

    IEC 320-C16

    IEC 320-C16

    Specifications

    Parameter Specification Parameter Specification
    Model PWR-C5-1KWAC/2 Rated Power 1000 W
    Input Voltage 100 – 240 VAC, 50 – 60 Hz Input Current 12 – 6 A
    Output Voltage 54 VDC Output Current 16.5 A
    Holdup Time ≥ 20 ms at 100 VAC Total Output BTU/hr 3412 BTU/hr
    Dimensions (H × W × D) 1.58″ × 4.0″ × 7.6″ Weight 2 lb (0.9 kg)

    Get More Information

    Discover unbeatable prices and fast shipping for the PWR-C5-1KWAC/2 Access the detailed PWR-C5-1KWAC/2 datasheet and ensure you’re getting the best deal with our reliable delivery service. Need assistance? Our free live chat support is here to help. For more information about the product and pricing, contact us via Live chat or email us at [email protected]

    Quality Certifications

    Customer Reviews

    Write A Review
    5.0
    (11 reviews)
    5 Stars
    11
    4 Stars
    0
    3 Stars
    0
    2 Stars
    0
    1 Stars
    0
      Chris Evans
      Posted on 08/07/2025
      Verified Buyer
      5.0

      Security seals intact. Authentic equipment. Good job.

      Tony Stark
      Posted on 30/05/2025
      Verified Buyer
      5.0

      Fastest delivery I’ve seen. Logistics team is on point.

      Facility Mgr
      Posted on 25/03/2025
      Verified Buyer
      5.0

      Bulk order arrived on a pallet. Very well wrapped and secured.

      Procurement
      Posted on 15/01/2025
      Verified Buyer
      5.0

      Hard to find stock lately, but you guys delivered on time.

      Maeve James
      Posted on 12/05/2024
      Verified Buyer
      5.0

      Excellent product, will order again for new sites.

    Questions & Answers

    • What should I do if my pair of 1KW C5 modules fail to power up?

      Check both power cords and outlets, ensure both modules are fully seated, and inspect the LEDs for fault indicators. Reseat or swap modules to identify any faulty units.
    • Is all required hardware included in the C5 dual 1KW kit?

      Yes, the kit includes two power supplies, two power cords, mounting brackets, screws, and usually a quick install guide.
    • What are the main distinctions between a single and dual 1KW module setup?

      The dual configuration offers power redundancy—if one fails, the other keeps the switch online—while a single module does not provide backup.
    • Can I use other models for this power slot?

      Use only Cisco-recommended supplies for safety and best results. Consult your switch’s compatibility list for valid options.
    • In which networks is a redundant 1KW power set most useful?

      Mission-critical sites such as enterprise cores, data centers, or large campus deployments where downtime is unacceptable.
    • Are there best practices for safe installation of this power pair?

      Shut off power to both modules, let the chassis discharge, and use ESD protection during handling.
    • Does this solution fit all supported C5 hardware?

      Only certain C5-compatible switches have slots for dual supplies—check your device datasheet.
    • How to check if both 1KW modules are running properly?

      Use `show environment power` or similar CLI to view the status and health of each module.
    • Is there a firmware requirement for these dual supplies?

      No special firmware for the supplies, but ensure your switch runs up-to-date IOS-XE for best compatibility.
    • Which LEDs on the supply signal errors?

      Red or amber LEDs indicate faults; refer to documentation for error code details.
    • What’s the maintenance interval recommended by Cisco?

      Quarterly inspection is standard; clean and check more frequently in challenging environments.
    • Does the switch support hot-swap for this dual set?

      Yes, most supported Catalyst switches allow hot-swapping one module while the other stays active.
    • Can the power system run if only one module is operational?

      Yes, as long as the power demand doesn’t exceed one module’s capacity, the switch will stay online.
    • Where to download official install and troubleshooting manuals?

      All documents are available on the Cisco Support site under your product ID.
    • How to spot counterfeit modules in a kit?

      Look for Cisco logos, official part numbers, and purchase through authorized resellers.
    • Are there ideal temperature or humidity guidelines?

      Operate at 0–40°C (32–104°F) and humidity below 85% for optimal performance.
    • Can remote monitoring detect failure on this dual unit?

      Yes, use network management tools or the switch CLI to get alerts and module health information.
    • Is cable management different with two modules?

      Ensure each power cord is routed to avoid tension and maintain airflow to both modules.
    • What steps to take if only one supply is detected?

      Reseat both modules, swap positions, check power cords, and use CLI to troubleshoot.
    • What is Cisco’s process for return and replacement?

      Open a case with Cisco TAC or contact your reseller for RMA and warranty processing.

    Warranty

    Standard Services

    Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.

    • Projects and Technical Support
    • Easy Purchasing Supply
    • Product Lifecycle Protection
    • Exclusive F3 Team Support

    Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.

    Shipping

    Resources Downloads

    • PWR-C5-1KWAC-2 Datasheet

    Product Tag