SFP-25G-ER-I – 25GBASE-ER SFP28 – 40km SMF – Industrial Temp

  • 100% Genuine
    Brand-new Cisco hardware
  • SN Verifiable
    Verify before shipment
    -> Check SN
  • 3-Year Warranty
    Extended, enterprise-grade
(8 customer reviews)
Questions

7/mo Solds

List Price: $28,050.28 77% OFF
$6,520.00
Related Condition
Quantity
Trusted & Secure Payments
Shipping Express Shipping 2-6 Business Days, via UPS, FedEx, DHL and more

Stable Global Supply Chain for Thriving Businesses.

  • $8,000,000 Inventory
  • Certified Cisco Partner ships
  • Collaborating with FedEx, UPS, DHL

Free Expert Support from Planning to Deployment

  • Assistance with product selection and network solution design
  • Configuration guidance and best-practice recommendations
  • Troubleshooting support provided by CCIE-level technical experts

Established Global IT Distributor

With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.

SFP-25G-ER-I Description

SFP-25G-ER-I is a Cisco 25GBASE-ER SFP28 industrial-temperature optical transceiver for 25 Gigabit Ethernet links that need long-reach single-mode fiber connectivity. It supports 40 km operation over standard ITU-T G.652 single-mode fiber, uses a dual LC/PC connector with 1310 nm optics, requires RS-FEC on host ports for full 25G reach, and is specified for -40 to 85 degrees C industrial environments with 1.5W maximum power consumption.

Quick Specs

Parameter

Specification

Product ID

SFP-25G-ER-I

Product type

Industrial-temperature 25GBASE-ER SFP28 transceiver

Ethernet rate

25 Gigabit Ethernet

Fiber type

Standard single-mode fiber

SMF reference

ITU-T G.652

Nominal wavelength

1310 nm

Operating distance

40 km

Connector

Dual LC/PC

Host FEC requirement

RS-FEC on host ports for full reach at 25G

Maximum power consumption

1.5W

Operating temperature class

Industrial -40 to 85 degrees C

Application Scenarios

Industrial 25G ER fiber spans

SFP-25G-ER-I fits supported Cisco SFP28 ports where the fiber plan needs a 25G ER transceiver and the site temperature range rules out commercial-temperature optics.

Long duplex SMF uplink planning

For campus, aggregation, or service-edge paths that approach the 40 km class, this SKU keeps the BOM tied to duplex G.652 SMF, RS-FEC, and Cisco’s engineered-link note for distances greater than 30 km.

Avoiding BiDi and LR substitutions

Use a separate order line for SFP-25G-ER-I when the design is duplex ER. The bidirectional SFP-25G-BX40D-I and SFP-25G-BX40U-I parts are matched single-fiber variants, and SFP-10/25G-LR-I stays in the shorter LR family.

Product Comparison

Parameter

SFP-25G-ER-I

SFP-10/25G-LR-I

SFP-25G-BX40D-I

SFP-25G-BX40U-I

Product type

25GBASE-ER SFP28 industrial transceiver

10/25GBASE-LR SFP28 industrial transceiver

25GBASE-BR40 SFP28 BiDi industrial transceiver

25GBASE-BR40 SFP28 BiDi industrial transceiver

Supported Ethernet rate

25 Gigabit Ethernet

10 and 25 Gigabit Ethernet

25 Gigabit Ethernet

25 Gigabit Ethernet

Fiber type

Standard SMF

Standard SMF

Standard SMF

Standard SMF

Fiber reference

G.652

G.652

G.652

G.652

Fiber topology

Duplex SMF

Duplex SMF

Single-fiber bidirectional downstream

Single-fiber bidirectional upstream

Nominal wavelength

1310 nm

1310 nm

1314 nm transmit and 1289 nm receive

1289 nm transmit and 1314 nm receive

Documented reach

40 km

10 km

40 km

40 km

Host FEC requirement

RS-FEC for full reach at 25G

RS-FEC for full reach at 25G

RS-FEC for full reach at 25G

RS-FEC for full reach at 25G

Maximum power consumption

1.5W

1.3W

1.9W

1.9W

Pull tab or bail latch color

Red

Blue

Red

Red

Ordering description

25GBASE-ER SFP28 Module for SMF Industrial Temp

10/25GBASE-LR SFP28 Module for SMF Industrial Temp

25GBASE-BR40 SFP28 BiDi module for SMF Industrial Temp Downstream

25GBASE-BR40 SFP28 BiDi module for SMF Industrial Temp Upstream

  • In a SFP-25G-ER-I vs SFP-10/25G-LR-I comparison, the table changes from a 40 km 25G ER order line to a 10 km 10/25G LR order line, while both remain industrial-temperature SMF modules.
  • The SFP-25G-ER-I difference from SFP-25G-BX40D-I is fiber topology and wavelength pairing: SFP-25G-ER-I is a duplex ER optic, while SFP-25G-BX40D-I is the downstream member of a single-fiber bidirectional pair.
  • SFP-25G-ER-I vs SFP-25G-BX40U-I is the matching upstream-side comparison for the same BiDi family; the table keeps reach aligned but changes the transmit and receive wavelengths.
  • For which model to choose, match the duplex or single-fiber design, reach class, temperature class, RS-FEC support, and Cisco host-support entry before replacing one industrial 25G SFP28 SKU with another.

Selection Guide

1. Select it for duplex 40 km ER

Choose SFP-25G-ER-I when the bill of materials calls for Cisco 25GBASE-ER over two-strand G.652 single-mode fiber and the intended host has official Cisco support.

2. Keep LR-I for shorter dual-rate needs

Use SFP-10/25G-LR-I where the deployment needs the Cisco industrial LR family, 10 km reach, or the documented 10G and 25G dual-rate scope rather than a single-rate 25G ER optic.

3. Use the BX40 pair only for single-fiber links

Order SFP-25G-BX40D-I with SFP-25G-BX40U-I when the design uses Cisco’s single-fiber bidirectional 40 km path, not when the fiber plant is a duplex ER pair.

4. Check engineered-link conditions early

For SFP-25G-ER-I spans beyond 30 km, keep the fiber-loss record and RS-FEC setting with the quote package so the deployment is reviewed as an engineered link.

Ordering Checklist

Check Item

What to Confirm

Procurement Risk Controlled

Cisco host support

Target switch, port, and software release are checked in Cisco compatibility documentation

Avoids approving the optic from SFP28 form factor and 25G speed alone

Fiber topology

Cabling plan uses duplex G.652 single-mode fiber for the ER link

Prevents substituting single-fiber BiDi optics into a two-strand design or the reverse

RS-FEC readiness

Host ports can use RS-FEC for full-reach 25G operation

Reduces turn-up risk on long 25G ER paths

Industrial temperature need

Site conditions require Cisco’s -40 to 85 degrees C industrial range

Keeps the industrial SKU tied to a real environmental requirement

Connector plan

Patch cords use LC/PC or LC/UPC ends and avoid APC connectors

Matches Cisco’s connector rule for the SFP28 optical link

Link engineering record

Fiber loss and path details are reviewed when the span is greater than 30 km

Keeps the 40 km order tied to Cisco’s engineered-link note

Specifications

Parameter Specification Parameter Specification
Product ID SFP-25G-ER-I Product type Industrial-temperature 25GBASE-ER SFP28 transceiver
Ordering description 25GBASE-ER SFP28 Module for SMF Industrial Temp Ethernet rate 25 Gigabit Ethernet
Receiver electrical interface Limiting Form factor SFP28
Fiber type Standard single-mode fiber SMF reference ITU-T G.652
Nominal wavelength 1310 nm Transmit and receive wavelength range 1295 to 1310 nm
Operating distance 40 km Engineered-link note Links greater than 30 km are engineered links
Transmit power range +6.0 to -3.0 dBm Receive power range -4.0 to -21.0 dBm
Connector Dual LC/PC Patch-cord rule PC or UPC connectors supported
Pull tab color Red Maximum power consumption 1.5W
Host FEC requirement RS-FEC on host ports for full reach at 25G Operating temperature class Industrial
Industrial operating temperature -40 to 85 degrees C Storage temperature range -40 to 85 degrees C
Standards references SFF-8402, SFF-8472, IEEE 802.3, IEEE P802.3by, IEEE P802.3cc Standard warranty 5 years
Platform support boundary Cisco host platform and software support must be verified in the Transceiver Module Group Compatibility Matrix    

Get More Information

Need pricing, stock, or shipping details for the SFP-25G-ER-I ? Layer23-Switch can help you check current availability, lead time, and delivery options for this. Send us the part number, quantity, and destination country via live chat or email sales@layer23-switch.com for a fast quotation.

Quality Certifications

Customer Reviews

Write A Review
4.9
(8 reviews)
5 Stars
7
4 Stars
1
3 Stars
0
2 Stars
0
1 Stars
0
    Michelle Scott
    Posted on 02/03/2026
    Verified Buyer
    4.0

    Layer23 doesn’t disappear after they take your money. Solid support throughout.

    Timothy Rivas
    Posted on 11/02/2026
    Verified Buyer
    5.0

    Operational from day one. No teething problems.

    Ravi Costa
    Posted on 03/02/2026
    Verified Buyer
    5.0

    The per-unit cost made it feasible to standardize across all our locations.

    Joel Miller
    Posted on 12/10/2024
    Verified Buyer
    5.0

    It works. That’s what matters. Delivery was on time.

    Kratos
    Posted on 30/07/2024
    Verified Buyer
    5.0

    Boy… the package has arrived. It is strong. It is good.

Questions & Answers

  • What distance does SFP-25G-ER-I target?

    SFP-25G-ER-I is a 25GBASE-ER SFP28 optic for 40km links over G.652 single-mode fiber or SMF at 25G.
  • Why does SFP-25G-ER-I require tighter link budgeting?

    SFP-25G-ER-I spans 40km so receive power and fiber loss need engineering against Cisco optical limits before deployment on SMF paths.
  • Is SFP-25G-ER-I a dual-rate 10G optic?

    SFP-25G-ER-I is positioned as a 25G ER module; dual-rate 10G/25G LR questions belong to SFP-10/25G-LR-I instead of ER-I.
  • What temperature profile does SFP-25G-ER-I provide?

    SFP-25G-ER-I has an industrial temperature range which separates it from standard short-reach data-center optics used in controlled rooms.
  • Which fiber type belongs with SFP-25G-ER-I?

    SFP-25G-ER-I uses 1310nm single-mode fiber or SMF and does not belong on multimode OM3 or OM4 patch infrastructure.
  • Why is RS-FEC important for SFP-25G-ER-I?

    SFP-25G-ER-I requires RS-FEC on the host port for full 40km reach and stable 25G operation across long fiber spans.
  • When does SFP-25G-ER-I replace SFP-10/25G-LR-I?

    SFP-25G-ER-I fits 25G single-mode spans beyond 10km while SFP-10/25G-LR-I stays aligned to 10km LR links on SMF circuits.
  • Which ordering mistake affects SFP-25G-ER-I?

    SFP-25G-ER-I gets misordered when a project only needs 10km LR reach or needs dual-rate 10G/25G operation on SMF.

Warranty

Visit How to Pay page for more information

EOL EOSL checker
Check lifecycle dates
FREE NETWORK TOOLS

Verify, plan, and comparewith confidence

Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.

Standard Services

Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.

  • Projects and Technical Support
  • Easy Purchasing Supply
  • Product Lifecycle Protection
  • Exclusive F3 Team Support

Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.

Shipping

DataSheet Downloads

  • SFP-25G-ER-I Datasheet