SFP-25G-ER-I – 25GBASE-ER SFP28 – 40km SMF – Industrial Temp
7/mo Solds
Established Global IT Distributor
With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.
SFP-25G-ER-I Description
SFP-25G-ER-I is a Cisco 25GBASE-ER SFP28 industrial-temperature optical transceiver for 25 Gigabit Ethernet links that need long-reach single-mode fiber connectivity. It supports 40 km operation over standard ITU-T G.652 single-mode fiber, uses a dual LC/PC connector with 1310 nm optics, requires RS-FEC on host ports for full 25G reach, and is specified for -40 to 85 degrees C industrial environments with 1.5W maximum power consumption.
Quick Specs
|
Parameter |
Specification |
|---|---|
|
Product ID |
SFP-25G-ER-I |
|
Product type |
Industrial-temperature 25GBASE-ER SFP28 transceiver |
|
Ethernet rate |
25 Gigabit Ethernet |
|
Fiber type |
Standard single-mode fiber |
|
SMF reference |
ITU-T G.652 |
|
Nominal wavelength |
1310 nm |
|
Operating distance |
40 km |
|
Connector |
Dual LC/PC |
|
Host FEC requirement |
RS-FEC on host ports for full reach at 25G |
|
Maximum power consumption |
1.5W |
|
Operating temperature class |
Industrial -40 to 85 degrees C |
Application Scenarios
SFP-25G-ER-I fits supported Cisco SFP28 ports where the fiber plan needs a 25G ER transceiver and the site temperature range rules out commercial-temperature optics.
For campus, aggregation, or service-edge paths that approach the 40 km class, this SKU keeps the BOM tied to duplex G.652 SMF, RS-FEC, and Cisco’s engineered-link note for distances greater than 30 km.
Use a separate order line for SFP-25G-ER-I when the design is duplex ER. The bidirectional SFP-25G-BX40D-I and SFP-25G-BX40U-I parts are matched single-fiber variants, and SFP-10/25G-LR-I stays in the shorter LR family.
Product Comparison
|
Parameter |
SFP-25G-ER-I |
SFP-25G-BX40D-I |
SFP-25G-BX40U-I | |
|---|---|---|---|---|
|
Product type |
25GBASE-ER SFP28 industrial transceiver |
10/25GBASE-LR SFP28 industrial transceiver |
25GBASE-BR40 SFP28 BiDi industrial transceiver |
25GBASE-BR40 SFP28 BiDi industrial transceiver |
|
Supported Ethernet rate |
25 Gigabit Ethernet |
10 and 25 Gigabit Ethernet |
25 Gigabit Ethernet |
25 Gigabit Ethernet |
|
Fiber type |
Standard SMF |
Standard SMF |
Standard SMF |
Standard SMF |
|
Fiber reference |
G.652 |
G.652 |
G.652 |
G.652 |
|
Fiber topology |
Duplex SMF |
Duplex SMF |
Single-fiber bidirectional downstream |
Single-fiber bidirectional upstream |
|
Nominal wavelength |
1310 nm |
1310 nm |
1314 nm transmit and 1289 nm receive |
1289 nm transmit and 1314 nm receive |
|
Documented reach |
40 km |
10 km |
40 km |
40 km |
|
Host FEC requirement |
RS-FEC for full reach at 25G |
RS-FEC for full reach at 25G |
RS-FEC for full reach at 25G |
RS-FEC for full reach at 25G |
|
Maximum power consumption |
1.5W |
1.3W |
1.9W |
1.9W |
|
Pull tab or bail latch color |
Red |
Blue |
Red |
Red |
|
Ordering description |
25GBASE-ER SFP28 Module for SMF Industrial Temp |
10/25GBASE-LR SFP28 Module for SMF Industrial Temp |
25GBASE-BR40 SFP28 BiDi module for SMF Industrial Temp Downstream |
25GBASE-BR40 SFP28 BiDi module for SMF Industrial Temp Upstream |
- In a SFP-25G-ER-I vs SFP-10/25G-LR-I comparison, the table changes from a 40 km 25G ER order line to a 10 km 10/25G LR order line, while both remain industrial-temperature SMF modules.
- The SFP-25G-ER-I difference from SFP-25G-BX40D-I is fiber topology and wavelength pairing: SFP-25G-ER-I is a duplex ER optic, while SFP-25G-BX40D-I is the downstream member of a single-fiber bidirectional pair.
- SFP-25G-ER-I vs SFP-25G-BX40U-I is the matching upstream-side comparison for the same BiDi family; the table keeps reach aligned but changes the transmit and receive wavelengths.
- For which model to choose, match the duplex or single-fiber design, reach class, temperature class, RS-FEC support, and Cisco host-support entry before replacing one industrial 25G SFP28 SKU with another.
Selection Guide
1. Select it for duplex 40 km ER
Choose SFP-25G-ER-I when the bill of materials calls for Cisco 25GBASE-ER over two-strand G.652 single-mode fiber and the intended host has official Cisco support.
2. Keep LR-I for shorter dual-rate needs
Use SFP-10/25G-LR-I where the deployment needs the Cisco industrial LR family, 10 km reach, or the documented 10G and 25G dual-rate scope rather than a single-rate 25G ER optic.
3. Use the BX40 pair only for single-fiber links
Order SFP-25G-BX40D-I with SFP-25G-BX40U-I when the design uses Cisco’s single-fiber bidirectional 40 km path, not when the fiber plant is a duplex ER pair.
4. Check engineered-link conditions early
For SFP-25G-ER-I spans beyond 30 km, keep the fiber-loss record and RS-FEC setting with the quote package so the deployment is reviewed as an engineered link.
Ordering Checklist
|
Check Item |
What to Confirm |
Procurement Risk Controlled |
|---|---|---|
|
Cisco host support |
Target switch, port, and software release are checked in Cisco compatibility documentation |
Avoids approving the optic from SFP28 form factor and 25G speed alone |
|
Fiber topology |
Cabling plan uses duplex G.652 single-mode fiber for the ER link |
Prevents substituting single-fiber BiDi optics into a two-strand design or the reverse |
|
RS-FEC readiness |
Host ports can use RS-FEC for full-reach 25G operation |
Reduces turn-up risk on long 25G ER paths |
|
Industrial temperature need |
Site conditions require Cisco’s -40 to 85 degrees C industrial range |
Keeps the industrial SKU tied to a real environmental requirement |
|
Connector plan |
Patch cords use LC/PC or LC/UPC ends and avoid APC connectors |
Matches Cisco’s connector rule for the SFP28 optical link |
|
Link engineering record |
Fiber loss and path details are reviewed when the span is greater than 30 km |
Keeps the 40 km order tied to Cisco’s engineered-link note |
Specifications
| Parameter | Specification | Parameter | Specification |
|---|---|---|---|
| Product ID | SFP-25G-ER-I | Product type | Industrial-temperature 25GBASE-ER SFP28 transceiver |
| Ordering description | 25GBASE-ER SFP28 Module for SMF Industrial Temp | Ethernet rate | 25 Gigabit Ethernet |
| Receiver electrical interface | Limiting | Form factor | SFP28 |
| Fiber type | Standard single-mode fiber | SMF reference | ITU-T G.652 |
| Nominal wavelength | 1310 nm | Transmit and receive wavelength range | 1295 to 1310 nm |
| Operating distance | 40 km | Engineered-link note | Links greater than 30 km are engineered links |
| Transmit power range | +6.0 to -3.0 dBm | Receive power range | -4.0 to -21.0 dBm |
| Connector | Dual LC/PC | Patch-cord rule | PC or UPC connectors supported |
| Pull tab color | Red | Maximum power consumption | 1.5W |
| Host FEC requirement | RS-FEC on host ports for full reach at 25G | Operating temperature class | Industrial |
| Industrial operating temperature | -40 to 85 degrees C | Storage temperature range | -40 to 85 degrees C |
| Standards references | SFF-8402, SFF-8472, IEEE 802.3, IEEE P802.3by, IEEE P802.3cc | Standard warranty | 5 years |
| Platform support boundary | Cisco host platform and software support must be verified in the Transceiver Module Group Compatibility Matrix |
Get More Information
Need pricing, stock, or shipping details for the SFP-25G-ER-I ? Layer23-Switch can help you check current availability, lead time, and delivery options for this. Send us the part number, quantity, and destination country via live chat or email sales@layer23-switch.com for a fast quotation.
Quality Certifications
Customer Reviews
Questions & Answers
-
What distance does SFP-25G-ER-I target?
-
Why does SFP-25G-ER-I require tighter link budgeting?
-
Is SFP-25G-ER-I a dual-rate 10G optic?
-
What temperature profile does SFP-25G-ER-I provide?
-
Which fiber type belongs with SFP-25G-ER-I?
-
Why is RS-FEC important for SFP-25G-ER-I?
-
When does SFP-25G-ER-I replace SFP-10/25G-LR-I?
-
Which ordering mistake affects SFP-25G-ER-I?
Warranty
Layer23-Switch.com offers genuine, high-quality ICT products at competitive wholesale prices—ensuring exceptional value without compromising quality.
All items are brand new, original, and factory-sealed.
Upon request, each unit can be fully tested and verified by a Cisco CCIE-certified engineer to ensure perfect working condition before shipment.
Our Cisco CCIE-certified experts provide free professional support via phone, email, online chat, or remote login—helping you deploy and troubleshoot with confidence.
If you are not satisfied with your purchase, you may request an exchange or full refund. Our customer service team will guide you through the return process quickly and smoothly. Visit Return Policy page for more information.
We support multiple secure payment and logistics options, backed by industry-leading verification:












Visit How to Pay page for more information
Extended, Worry-Free Warranty Coverage Factory New Sealed Enterprise Hardware:
· 3 Years Factory New Sealed
Visit Warranty Policy page for more information
Verify, plan, and comparewith confidence
Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.
Standard Services
Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.
- Projects and Technical Support
- Easy Purchasing Supply
- Product Lifecycle Protection
- Exclusive F3 Team Support
Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.
Layer23 doesn’t disappear after they take your money. Solid support throughout.
Operational from day one. No teething problems.
The per-unit cost made it feasible to standardize across all our locations.
It works. That’s what matters. Delivery was on time.
Boy… the package has arrived. It is strong. It is good.