N9K-C9364C – 64×40/100G QSFP28 – 2×1/10G SFP+ – 2RU Spine Switch

4.86 reviews6 Questions5 sold this month
List Price: $88,410.27 91% OFF
$7,820.00
Price Alert
In StockShips in as little as 1 business day Brand New
Related models
Cisco SN CheckSN verification before shipment.Verify authenticity3-Year WarrantyExtended, enterprise-gradeWarranty terms14-Day ReturnsStraightforward RMA processReturn policyExpress Shipping2-6 Business Daysvia UPS, FedEx, DHL and more
Trusted & Secure Payments

Why Layer23-Switch

Stocked, Shipped and Supported by One Team

Founded
Customers
Units shipped
Countries

Inventory You Can See

Cisco stock on hand
Models ready to ship
Warehouse space

Ships in 1 Business Day

In-stock orders leave our Hong Kong or U.S. warehouse within 1 business day after payment, with tracking by email.

DHL FedEx UPS Duties included: US · CA · UK

LSCare Warranty

3years on enterprise equipment

  • Advance replacement for in-stock models
  • New unit for dead-on-arrival
  • 14-day returns on sealed items

Free CCIE Support

Certified engineers help before and after you buy. Reply within 1 business day by email or live chat.

Part number check Configuration Troubleshooting

Verify Before You Pay

100%factory-sealed

Get label and serial photos before shipment, and check every serial number with Cisco.

N9K-C9364C Description

The N9K-C9364C is a Cisco Nexus 9000 ACI Spine fixed switch for 2RU spine racks that run ACI Spine or NX-OS mode over 40/100G fabric links. The switch has 64 40/100G QSFP28 ports, 2 1/10G SFP+ ports, 12.84 Tbps of switching bandwidth and 4.3 bpps of forwarding, with 32 GB of system memory and a 40 MB buffer. Breakout cables are not supported, and 1+1 redundancy on a 100-120 VAC feed is not available because that input limits output to 800W.

Quick Specs

Parameter

Specification

Product ID

N9K-C9364C

Product type

2RU fixed-port data center switch

High-speed ports

64 x 40/100G QSFP28

Additional Ethernet ports

2 x 1/10G SFP+

Operating mode

Cisco ACI Spine or Cisco NX-OS

Switching capacity

12.84 Tbps

Forwarding rate

4.3 bpps

Packet buffer

40 MB

DRAM

32 GB

SSD storage

128 GB

Power supply options

1200W AC, 930W DC, or 1200W HVAC/HVDC

Airflow options

Port-side intake or port-side exhaust

Product Performance

Switching Bandwidth
Fixed 40/100G Port Density
Forwarding Rate

Key Features

64 QSFP28 Ports In 2RU

Sixty-four fixed 40/100G QSFP28 ports sit in a 2RU chassis. That is double the port count of the 1RU 32-port Nexus 9332C.

12.84 Tbps Switching Bandwidth

Bandwidth reaches 12.84 Tbps with 4.3 bpps of forwarding. A 40 MB system buffer and 32 GB of memory support the load.

MACsec On The Last 16 Ports

Wire-rate MACsec encryption is available on the last 16 ports, marked green on the chassis. Encrypted leaf-to-spine links are mapped to those ports.

No Breakout Cables

Breakout cables are not supported. Each port carries one 40G or 100G link.

Three Power Supply Families

The chassis takes 1200W AC, 930W DC or 1200W HVAC/HVDC supplies in a 1+1 pair. The two supplies must be the same type.

ACI Spine Or NX-OS Mode

The same hardware runs Cisco ACI Spine or NX-OS mode, with port-side intake or exhaust fans selected to match the supplies.

Application Scenarios

ACI Spine In A Leaf Fabric

In an ACI fabric, the switch sits at the spine layer with 64 40/100G QSFP28 ports that each connect to a leaf switch uplink.

NX-OS Aggregation Block

A data center running NX-OS can aggregate leaf switches and service blocks on the QSFP28 ports, while the two SFP+ ports carry 1G or 10G connections for auxiliary equipment.

Native 100G Cabling Plan

A fabric cabled for native 40G or 100G links fits the switch directly, because the platform supports no breakout cables and every port runs at its own rate.

Product Comparison

Parameter

N9K-C9364C

N9K-C9332C

N9K-C93600CD-GX

Ports

64 x 40/100G QSFP28 and 2 x 1/10G SFP+

32 x 40/100G QSFP28 and 2 x 1/10G SFP+

28 x 100/40-Gbps QSFP28 and 8 x 400/100-Gbps QSFP-DD

Physical dimensions (H x W x D)

2RU: 3.38 x 17.37 x 22.27 in.

1RU: 1.7 x 17.3 x 22.9 in.

1RU: 1.72 x 17.37 x 25.5 in.

Switching capacity

12.84 Tbps

6.4 Tbps

12 Tbps

DRAM

32 GB

16 GB

32 GB

Packet buffer

40 MB

40 MB

80 MB

Breakout cables

Not supported

Not supported

Supported by port range

MACsec-capable ports

Last 16 ports

Last 8 ports

Not published

Power supplies

1200W AC, 930W DC or 1200W HVAC/HVDC

750W AC, 1100W AC, 1100W DC or 1100W HVAC/HVDC

1100W AC, DC or HVAC/HVDC

Airflow

Port-side intake or exhaust

Port-side intake or exhaust

Port-side intake or exhaust

N9K-C9364C is the 64-port model of this pair: it fits 64 40/100G QSFP28 ports in 2RU at 12.84 Tbps with 32 GB of memory, while N9K-C9332C holds 32 ports in 1RU at 6.4 Tbps with 16 GB. MACsec follows the same split, on the last 16 QSFP28 ports of N9K-C9364C and the last 8 of N9K-C9332C. A rack that has only 1RU free and needs 32 or fewer 100G ports points to N9K-C9332C. A design that needs breakout cables or 400G interfaces has to leave this pair, because neither supports breakout cables; N9K-C93600CD-GX supports breakout by port range, adds 8 QSFP-DD ports and doubles the buffer to 80 MB against 40 MB.

Ordering Checklist

  • Fan modules: Order NXA-FAN-160CFM-PE (exhaust, blue) or NXA-FAN-160CFM-PI (intake, burgundy). Fans and power supplies must share one airflow direction, so the PE or PI suffix has to match.
  • Power supplies: Select NXA-PAC-1200W-PE or -PI (AC), N9K-PUV-1200W (HVAC/HVDC, bidirectional airflow), or NXA-PDC-930W-PE or -PI (DC); the two supplies must be the same type. Mixing AC, DC and HVAC/HVDC supplies in one chassis is not allowed, and the bidirectional N9K-PUV-1200W follows the fan airflow on its own.
  • AC input voltage: Confirm whether the rack feed is 100-120 VAC or 200-240 VAC. On NXA-PAC-1200W a 100-120 VAC feed gives 800W output and no supply redundancy, against 1200W at 200-240 VAC.
  • DC redundancy: Run NXA-PDC-930W redundant only at 40 degrees C or below with 3.5W QSFP+ or passive QSFP cables; otherwise both supplies must run. Outside those limits the 1+1 DC pair gives no redundancy.
  • Power cords: Add CAB-HVDC-3T-2M, CAB-HVAC-SD-0.6M, CAB-HVAC-RT-0.6M or CAB-48DC-40A-8AWG for HVDC, HVAC and -48VDC feeds, or the country AC cord. The supply arrives without a usable cord if the cord PID is left off the order.
  • 100G SR4 optics: Check QSFP-100G-SR4-S (Part# 10-3142-02 or 10-3142-01) quantities above 40 per switch. More than 40 of these optics do not meet the EMC radiated emissions standard.
  • Rack kit: Add N9K-C9300-RMK or N9K-C9300-ACK from the accessory list. The mounting hardware is a separate accessory line on the order table.

Optional Add-ons

Model

Description

NXA-FAN-160CFM-PI

Cisco Nexus fan with port-side intake airflow

NXA-FAN-160CFM-PE

Cisco Nexus fan with port-side exhaust airflow

NXA-PAC-1200W-PI

Cisco Nexus 1200W AC power supply with port-side intake airflow

NXA-PAC-1200W-PE

Cisco Nexus 1200W AC power supply with port-side exhaust airflow

N9K-PUV-1200W

Cisco Nexus 1200W HVAC/HVDC dual-airflow power supply

NXA-PDC-930W-PI

Cisco Nexus 930W DC power supply with port-side intake airflow

NXA-PDC-930W-PE

Cisco Nexus 930W DC power supply with port-side exhaust airflow

N9K-C9300-RMK

Cisco Nexus 9300 rack mount kit

N9K-C9300-ACK

Cisco Nexus 9300 accessory kit

Nexus N9K-C9364C Front Panel

1

Beacon (BCN), Status (STS), and Environment (ENV) LEDs

5

Screw holes for front mounting brackets (four-post rack installations)

2

1-/10-Gigabit SFP+ ports (2)

6

Screw holes for center-mount bracket (two-post rack installations)

3

40-/100-Gigabit QSFP28 ports (ports 1 to 48 in 4 rows of 12 ports)

7

Notch on both sides of the chassis for locking the power supply end of the chassis to the bottom support rails (four-post rack installations).

4

Green colored 40-/100-Gigabit QSFP28 ports supporting MACsec (when software support is available) (ports 49 to 64 in 4 rows of 4 ports)

Nexus N9K-C9364C Rear Panel

1

Fan modules (3) with slots numbered from 1 (left) to 3 (right)

6

Grounding pad

2

Management port (1—RJ-45 copper port)

7

Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (top) and 2 (bottom)

3

Management port (1—SFP optical port)

8

Notch on both sides of the chassis for locking the power supply end of the chassis to the bottom support rails (four-post rack installations).

4

USB port (1)

9

Screw holes for center-mount bracket (two-post rack installations)

5

Console port (1)

10

Screw holes for front mounting brackets (four-post rack installations)

Specifications

Parameter Specification Parameter Specification
Product ID N9K-C9364C Product type Fixed-port data center switch
Rack units 2RU Operating modes Cisco ACI Spine or Cisco NX-OS
High-Speed ports 64 x 40/100G QSFP28 Additional Ethernet ports 2 x 1/10G SFP+
Management port 1 x 10/100/1000BASE-T and 1 x 1G SFP Console port 1 x RS-232
USB port 1 Switching capacity 12.84 Tbps
Forwarding rate 4.3 bpps Breakout cable support Not supported
MACsec-Capable ports Last 16 QSFP28 ports Packet buffer 40 MB
DRAM 32 GB SSD storage 128 GB
CPU Broadwell-DE 4 cores Power supply selection NXA-PAC-1200W-PI 1200W AC, NXA-PAC-1200W-PE 1200W AC, NXA-PDC-930W-PI 930W DC, NXA-PDC-930W-PE 930W DC, or N9K-PUV-1200W 1200W universal supply selected by input type
Power supply slots 2 modules, 1 for operation and 1 for redundancy Supported AC power supplies NXA-PAC-1200W-PI, NXA-PAC-1200W-PE
Supported DC power supplies NXA-PDC-930W-PI, NXA-PDC-930W-PE Supported HVAC/HVDC power supply N9K-PUV-1200W
930W DC redundancy note 1+1 redundancy requires 40C or lower ambient temperature and 3.5W QSFP+ modules or passive QSFP cables AC input voltage 100 to 240V AC
DC input voltage -40V to -72V DC AC input frequency 50 to 60 Hz
Airflow options Port-side intake or port-side exhaust Fan module options NXA-FAN-160CFM-PI, NXA-FAN-160CFM-PE
Airflow matching requirement Fans and power supplies should use the same airflow direction Typical power consumption 429W
Maximum power consumption 1245W Heat dissipation requirement 4248.116 BTU/hr
Dimensions 3.38 x 17.37 x 22.27 in. (8.59 x 44.13 x 56.58 cm) Weight with power supplies and fans 16.74 kg (36.9 lb)
Weight without power supplies and fans 12.43 kg (27.4 lb) Operating temperature 32 to 104F (0 to 40C)
Storage temperature -40 to 158F (-40 to 70C) Operating humidity 5 to 90% noncondensing
Operating altitude 0 to 13,123 ft (0 to 4,000 m) MTBF 257,860 hours
VLAN IDs 4096 with 127 reserved Maximum VRF instances 1,000
Maximum port channels 64 Maximum links in a port Channel 32
Maximum ECMP paths 64 Maximum VTEPs 256
Active SPAN sessions 4 RoHS compliance Yes
Supported optics reference Cisco transceiver support tables for supported modules and minimum releases Rack mount kit N9K-C9300-RMK
Accessory kit N9K-C9300-ACK

Quality Certifications

Customer Reviews

Write A Review
4.8
(6 reviews)
5 Stars
5
4 Stars
1
3 Stars
0
2 Stars
0
1 Stars
0
    Julie King
    Posted on 20/02/2026
    Verified Buyer
    5.0

    Worth giving them a try. You won’t regret it.

    Samantha Moore
    Posted on 03/01/2026
    Verified Buyer
    4.0

    Order arrived exactly as expected. Couldn’t be happier. Invoice formatting was a bit different from what our AP system expects, but workable.

    Jacqueline Tucker
    Posted on 01/01/2026
    Verified Buyer
    5.0

    Reorders flow smoothly because the first order set the right expectations.

    Winston
    Posted on 15/06/2024
    Verified Buyer
    5.0

    Impeccable service. A pleasure doing business.

    Infrastructure Mgr
    Posted on 28/02/2024
    Verified Buyer
    5.0

    Pallet was shrink-wrapped perfectly. No transit damage.

Questions & Answers

  • Does N9K-C9364C run in ACI mode or NX-OS mode?

    Yes, N9K-C9364C runs as a Cisco ACI spine or in Cisco NX-OS mode on the same hardware. In an ACI fabric it sits at the spine layer, with each of its 64 40/100G QSFP28 ports reaching a leaf switch uplink.
  • How is the airflow direction chosen on N9K-C9364C?

    Airflow on N9K-C9364C is port-side intake or port-side exhaust, set by the fan and supply PIDs. Order NXA-FAN-160CFM-PE for exhaust or NXA-FAN-160CFM-PI for intake, and match the PE or PI suffix on the AC and DC supplies. The HVAC/HVDC supply N9K-PUV-1200W is bidirectional and follows the fan airflow.
  • What maximum output do the power supplies for N9K-C9364C provide?

    The N9K-PUV-1200W supply for N9K-C9364C provides up to 1230 W maximum output. The NXA-PDC-930W DC supply provides 930 W from a nominal -48 to -72 Vdc feed, per the Nexus 9364C hardware installation guide. Order the DC supply only when the rack feed is -48 Vdc.
  • What humidity range and temperature limits apply to N9K-C9364C?

    N9K-C9364C operates at 0 to 40 C with 8 to 80% humidity, changing no faster than 10% per hour, at altitudes up to 4,000 m. Storage is rated -40 to 70 C. The rack intake must stay inside the 8 to 80% range, per the hardware installation guide.
  • How much does N9K-C9364C weigh and how deep is the chassis?

    N9K-C9364C weighs 27.4 lb (12.4 kg) and is 22.27 in. deep, per the hardware installation guide. An AC supply adds 2.64 lb and each fan adds 1.3 lb. The rack must support the loaded chassis weight.
  • Which ports on N9K-C9364C support MACsec?

    On N9K-C9364C, ports 49-64 are the green MACsec ports, and MACsec on them needs software support, per the hardware installation guide. Ports 1-48 are laid out in four rows of 12 and do not offer MACsec. Plan encrypted links on ports 49-64 only.

Warranty

Visit How to Pay page for more information

FREE NETWORK TOOLS

Verify, plan, and comparewith confidence

Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.

DataSheet Downloads

  • N9K-C9364C Datasheet