N9K-C9364C – 64×40/100G QSFP28 – 2×1/10G SFP+ – 2RU Spine Switch
Why Layer23-Switch
Stocked, Shipped and Supported by One Team
Ships in 1 Business Day
In-stock orders leave our Hong Kong or U.S. warehouse within 1 business day after payment, with tracking by email.
LSCare Warranty
3years on enterprise equipment
Free CCIE Support
Certified engineers help before and after you buy. Reply within 1 business day by email or live chat.
Verify Before You Pay
100%factory-sealed
Get label and serial photos before shipment, and check every serial number with Cisco.
N9K-C9364C Description
The N9K-C9364C is a Cisco Nexus 9000 ACI Spine fixed switch for 2RU spine racks that run ACI Spine or NX-OS mode over 40/100G fabric links. The switch has 64 40/100G QSFP28 ports, 2 1/10G SFP+ ports, 12.84 Tbps of switching bandwidth and 4.3 bpps of forwarding, with 32 GB of system memory and a 40 MB buffer. Breakout cables are not supported, and 1+1 redundancy on a 100-120 VAC feed is not available because that input limits output to 800W.
Quick Specs
|
Parameter |
Specification |
|---|---|
|
Product ID |
N9K-C9364C |
|
Product type |
2RU fixed-port data center switch |
|
High-speed ports |
64 x 40/100G QSFP28 |
|
Additional Ethernet ports |
2 x 1/10G SFP+ |
|
Operating mode |
Cisco ACI Spine or Cisco NX-OS |
|
Switching capacity |
12.84 Tbps |
|
Forwarding rate |
4.3 bpps |
|
Packet buffer |
40 MB |
|
DRAM |
32 GB |
|
SSD storage |
128 GB |
|
Power supply options |
1200W AC, 930W DC, or 1200W HVAC/HVDC |
|
Airflow options |
Port-side intake or port-side exhaust |
Product Performance
Key Features
Sixty-four fixed 40/100G QSFP28 ports sit in a 2RU chassis. That is double the port count of the 1RU 32-port Nexus 9332C.
Bandwidth reaches 12.84 Tbps with 4.3 bpps of forwarding. A 40 MB system buffer and 32 GB of memory support the load.
Wire-rate MACsec encryption is available on the last 16 ports, marked green on the chassis. Encrypted leaf-to-spine links are mapped to those ports.
Breakout cables are not supported. Each port carries one 40G or 100G link.
The chassis takes 1200W AC, 930W DC or 1200W HVAC/HVDC supplies in a 1+1 pair. The two supplies must be the same type.
The same hardware runs Cisco ACI Spine or NX-OS mode, with port-side intake or exhaust fans selected to match the supplies.
Application Scenarios
In an ACI fabric, the switch sits at the spine layer with 64 40/100G QSFP28 ports that each connect to a leaf switch uplink.
A data center running NX-OS can aggregate leaf switches and service blocks on the QSFP28 ports, while the two SFP+ ports carry 1G or 10G connections for auxiliary equipment.
A fabric cabled for native 40G or 100G links fits the switch directly, because the platform supports no breakout cables and every port runs at its own rate.
Product Comparison
|
Parameter |
N9K-C9364C | ||
|---|---|---|---|
|
Ports |
64 x 40/100G QSFP28 and 2 x 1/10G SFP+ |
32 x 40/100G QSFP28 and 2 x 1/10G SFP+ |
28 x 100/40-Gbps QSFP28 and 8 x 400/100-Gbps QSFP-DD |
|
Physical dimensions (H x W x D) |
2RU: 3.38 x 17.37 x 22.27 in. |
1RU: 1.7 x 17.3 x 22.9 in. |
1RU: 1.72 x 17.37 x 25.5 in. |
|
Switching capacity |
12.84 Tbps |
6.4 Tbps |
12 Tbps |
|
DRAM |
32 GB |
16 GB |
32 GB |
|
Packet buffer |
40 MB |
40 MB |
80 MB |
|
Breakout cables |
Not supported |
Not supported |
Supported by port range |
|
MACsec-capable ports |
Last 16 ports |
Last 8 ports |
Not published |
|
Power supplies |
1200W AC, 930W DC or 1200W HVAC/HVDC |
750W AC, 1100W AC, 1100W DC or 1100W HVAC/HVDC |
1100W AC, DC or HVAC/HVDC |
|
Airflow |
Port-side intake or exhaust |
Port-side intake or exhaust |
Port-side intake or exhaust |
N9K-C9364C is the 64-port model of this pair: it fits 64 40/100G QSFP28 ports in 2RU at 12.84 Tbps with 32 GB of memory, while N9K-C9332C holds 32 ports in 1RU at 6.4 Tbps with 16 GB. MACsec follows the same split, on the last 16 QSFP28 ports of N9K-C9364C and the last 8 of N9K-C9332C. A rack that has only 1RU free and needs 32 or fewer 100G ports points to N9K-C9332C. A design that needs breakout cables or 400G interfaces has to leave this pair, because neither supports breakout cables; N9K-C93600CD-GX supports breakout by port range, adds 8 QSFP-DD ports and doubles the buffer to 80 MB against 40 MB.
Ordering Checklist
- Fan modules: Order NXA-FAN-160CFM-PE (exhaust, blue) or NXA-FAN-160CFM-PI (intake, burgundy). Fans and power supplies must share one airflow direction, so the PE or PI suffix has to match.
- Power supplies: Select NXA-PAC-1200W-PE or -PI (AC), N9K-PUV-1200W (HVAC/HVDC, bidirectional airflow), or NXA-PDC-930W-PE or -PI (DC); the two supplies must be the same type. Mixing AC, DC and HVAC/HVDC supplies in one chassis is not allowed, and the bidirectional N9K-PUV-1200W follows the fan airflow on its own.
- AC input voltage: Confirm whether the rack feed is 100-120 VAC or 200-240 VAC. On NXA-PAC-1200W a 100-120 VAC feed gives 800W output and no supply redundancy, against 1200W at 200-240 VAC.
- DC redundancy: Run NXA-PDC-930W redundant only at 40 degrees C or below with 3.5W QSFP+ or passive QSFP cables; otherwise both supplies must run. Outside those limits the 1+1 DC pair gives no redundancy.
- Power cords: Add CAB-HVDC-3T-2M, CAB-HVAC-SD-0.6M, CAB-HVAC-RT-0.6M or CAB-48DC-40A-8AWG for HVDC, HVAC and -48VDC feeds, or the country AC cord. The supply arrives without a usable cord if the cord PID is left off the order.
- 100G SR4 optics: Check QSFP-100G-SR4-S (Part# 10-3142-02 or 10-3142-01) quantities above 40 per switch. More than 40 of these optics do not meet the EMC radiated emissions standard.
- Rack kit: Add N9K-C9300-RMK or N9K-C9300-ACK from the accessory list. The mounting hardware is a separate accessory line on the order table.
Optional Add-ons
|
Model |
Description |
|---|---|
|
NXA-FAN-160CFM-PI |
Cisco Nexus fan with port-side intake airflow |
|
NXA-FAN-160CFM-PE |
Cisco Nexus fan with port-side exhaust airflow |
|
NXA-PAC-1200W-PI |
Cisco Nexus 1200W AC power supply with port-side intake airflow |
|
NXA-PAC-1200W-PE |
Cisco Nexus 1200W AC power supply with port-side exhaust airflow |
|
N9K-PUV-1200W |
Cisco Nexus 1200W HVAC/HVDC dual-airflow power supply |
|
NXA-PDC-930W-PI |
Cisco Nexus 930W DC power supply with port-side intake airflow |
|
NXA-PDC-930W-PE |
Cisco Nexus 930W DC power supply with port-side exhaust airflow |
|
N9K-C9300-RMK |
Cisco Nexus 9300 rack mount kit |
|
N9K-C9300-ACK |
Cisco Nexus 9300 accessory kit |
Nexus N9K-C9364C Front Panel
|
1 5570_0e5cfa-a5> |
Beacon (BCN), Status (STS), and Environment (ENV) LEDs 5570_374535-fd> |
5 5570_98f762-0d> |
Screw holes for front mounting brackets (four-post rack installations) 5570_2a1350-48> |
|
2 5570_44ad2d-43> |
1-/10-Gigabit SFP+ ports (2) 5570_f4a0dc-4d> |
6 5570_5f44dc-d9> |
Screw holes for center-mount bracket (two-post rack installations) 5570_42e2ad-e9> |
|
3 5570_605dbb-ac> |
40-/100-Gigabit QSFP28 ports (ports 1 to 48 in 4 rows of 12 ports) 5570_f105bd-49> |
7 5570_234aca-d5> |
Notch on both sides of the chassis for locking the power supply end of the chassis to the bottom support rails (four-post rack installations). 5570_ccf92b-da> |
|
4 5570_f297b5-bf> |
Green colored 40-/100-Gigabit QSFP28 ports supporting MACsec (when software support is available) (ports 49 to 64 in 4 rows of 4 ports) 5570_036abd-53> | 5570_826280-67> | 5570_7c1762-8d> |
Nexus N9K-C9364C Rear Panel
|
1 5570_5f5e23-5f> |
Fan modules (3) with slots numbered from 1 (left) to 3 (right) 5570_76a0fd-04> |
6 5570_d04d65-6b> |
Grounding pad 5570_9863ef-0f> |
|
2 5570_d6a4ac-c0> |
Management port (1—RJ-45 copper port) 5570_4ba90a-a1> |
7 5570_d2a13d-13> |
Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (top) and 2 (bottom) 5570_fabd0c-6d> |
|
3 5570_3ee060-61> |
Management port (1—SFP optical port) 5570_cc9bac-3c> |
8 5570_5582bd-2e> |
Notch on both sides of the chassis for locking the power supply end of the chassis to the bottom support rails (four-post rack installations). 5570_e6420f-ef> |
|
4 5570_6c7f64-40> |
USB port (1) 5570_393d2b-ac> |
9 5570_a04d9d-2a> |
Screw holes for center-mount bracket (two-post rack installations) 5570_e3d8aa-c5> |
|
5 5570_be1906-a6> |
Console port (1) 5570_57fdc0-d2> |
10 5570_685c1d-d9> |
Screw holes for front mounting brackets (four-post rack installations) 5570_0ff71e-68> |
Specifications
| Parameter | Specification | Parameter | Specification |
|---|---|---|---|
| Product ID | N9K-C9364C | Product type | Fixed-port data center switch |
| Rack units | 2RU | Operating modes | Cisco ACI Spine or Cisco NX-OS |
| High-Speed ports | 64 x 40/100G QSFP28 | Additional Ethernet ports | 2 x 1/10G SFP+ |
| Management port | 1 x 10/100/1000BASE-T and 1 x 1G SFP | Console port | 1 x RS-232 |
| USB port | 1 | Switching capacity | 12.84 Tbps |
| Forwarding rate | 4.3 bpps | Breakout cable support | Not supported |
| MACsec-Capable ports | Last 16 QSFP28 ports | Packet buffer | 40 MB |
| DRAM | 32 GB | SSD storage | 128 GB |
| CPU | Broadwell-DE 4 cores | Power supply selection | NXA-PAC-1200W-PI 1200W AC, NXA-PAC-1200W-PE 1200W AC, NXA-PDC-930W-PI 930W DC, NXA-PDC-930W-PE 930W DC, or N9K-PUV-1200W 1200W universal supply selected by input type |
| Power supply slots | 2 modules, 1 for operation and 1 for redundancy | Supported AC power supplies | NXA-PAC-1200W-PI, NXA-PAC-1200W-PE |
| Supported DC power supplies | NXA-PDC-930W-PI, NXA-PDC-930W-PE | Supported HVAC/HVDC power supply | N9K-PUV-1200W |
| 930W DC redundancy note | 1+1 redundancy requires 40C or lower ambient temperature and 3.5W QSFP+ modules or passive QSFP cables | AC input voltage | 100 to 240V AC |
| DC input voltage | -40V to -72V DC | AC input frequency | 50 to 60 Hz |
| Airflow options | Port-side intake or port-side exhaust | Fan module options | NXA-FAN-160CFM-PI, NXA-FAN-160CFM-PE |
| Airflow matching requirement | Fans and power supplies should use the same airflow direction | Typical power consumption | 429W |
| Maximum power consumption | 1245W | Heat dissipation requirement | 4248.116 BTU/hr |
| Dimensions | 3.38 x 17.37 x 22.27 in. (8.59 x 44.13 x 56.58 cm) | Weight with power supplies and fans | 16.74 kg (36.9 lb) |
| Weight without power supplies and fans | 12.43 kg (27.4 lb) | Operating temperature | 32 to 104F (0 to 40C) |
| Storage temperature | -40 to 158F (-40 to 70C) | Operating humidity | 5 to 90% noncondensing |
| Operating altitude | 0 to 13,123 ft (0 to 4,000 m) | MTBF | 257,860 hours |
| VLAN IDs | 4096 with 127 reserved | Maximum VRF instances | 1,000 |
| Maximum port channels | 64 | Maximum links in a port Channel | 32 |
| Maximum ECMP paths | 64 | Maximum VTEPs | 256 |
| Active SPAN sessions | 4 | RoHS compliance | Yes |
| Supported optics reference | Cisco transceiver support tables for supported modules and minimum releases | Rack mount kit | N9K-C9300-RMK |
| Accessory kit | N9K-C9300-ACK |
Quality Certifications
Customer Reviews
Questions & Answers
-
Does N9K-C9364C run in ACI mode or NX-OS mode?
-
How is the airflow direction chosen on N9K-C9364C?
-
What maximum output do the power supplies for N9K-C9364C provide?
-
What humidity range and temperature limits apply to N9K-C9364C?
-
How much does N9K-C9364C weigh and how deep is the chassis?
-
Which ports on N9K-C9364C support MACsec?
Warranty
Layer23-Switch.com offers genuine, high-quality ICT products at competitive wholesale prices—ensuring exceptional value without compromising quality.
All items are brand new, original, and factory-sealed.
Upon request, each unit can be fully tested and verified by a Cisco CCIE-certified engineer to ensure perfect working condition before shipment.
Our Cisco CCIE-certified experts provide free professional support via phone, email, online chat, or remote login—helping you deploy and troubleshoot with confidence.
If you are not satisfied with your purchase, you may request an exchange or full refund. Our customer service team will guide you through the return process quickly and smoothly. Visit Return Policy page for more information.
We support multiple secure payment and logistics options, backed by industry-leading verification:












Visit How to Pay page for more information
Extended, Worry-Free Warranty Coverage Factory New Sealed Enterprise Hardware:
· 3 Years Factory New Sealed
Visit Warranty Policy page for more information
Verify, plan, and comparewith confidence
Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.
Worth giving them a try. You won’t regret it.
Order arrived exactly as expected. Couldn’t be happier. Invoice formatting was a bit different from what our AP system expects, but workable.
Reorders flow smoothly because the first order set the right expectations.
Impeccable service. A pleasure doing business.
Pallet was shrink-wrapped perfectly. No transit damage.