PWR-IE50W-AC – IE Switch Power Supply

(3 customer reviews)
Questions

0/mo Solds

List Price: $1489 $225
  • 100% Genuine
    Original, factory-authenticated
  • S/N Verifiable
    Verified by official serial-check
Condition New Factory Sealed Related Quantity
Trusted & Secure Payments
Shipping Express Shipping 2-6 Days, via DHL, FedEx, UPS, etc. Packaging weight and dimensions included:

Stable Global Supply Chain for Thriving Businesses.

  • $3,000,000 Inventory
  • Certified Cisco Partner ships
  • Collaborating with FedEx, UPS, DHL

Free Expert Support from Planning to Deployment

  • Assistance with product selection and network solution design
  • Configuration guidance and best-practice recommendations
  • Troubleshooting support provided by CCIE-level technical experts

Established Global IT Distributor

With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.

PWR-IE50W-AC Description

Cisco PWR-IE50W-AC is a compact 50W industrial DIN-rail power supply that converts AC mains into regulated 24V DC output for powering Cisco Industrial Ethernet switches, routers, and IoT gateways. Also referred to as the Cisco 50W AC industrial PSU, it delivers 2.1A at 24VDC, ensuring reliable power for edge networking devices in harsh environments. With universal AC 90–264V input and typical 80% efficiency, the unit provides stable operation across wide temperature ranges (-40°C to +75°C) and humidity conditions.Designed for DIN-rail mounting, the PWR-IE50W-AC is fanless, lightweight (0.64 kg), and has a high MTBF of over 1.6 million hours, making it ideal for mission-critical deployments. Built-in protections against over-voltage, over-current, over-temperature, and short circuit enhance reliability in industrial automation, transportation, utilities, and energy networks.

Quick Specs

Parameter

Specification

Model

PWR-IE50W-AC

Output Power

50W

Output Voltage / Current

24VDC, 2.1A

Input Voltage Range

AC 90–264V or DC 106–300V

Frequency

50/60 Hz

Efficiency (typical)

80%

Holdup Time @100% load

20 ms

Protections

Over Voltage, Over Current, Over Temperature, Short Circuit

Operating Temperature

-40°C to +75°C

Storage Temperature

-40°C to +85°C

Humidity

<95% RH (non-condensing)

MTBF

1,662,359 hours

Product Comparison

Parameter

PWR-IE50W-AC

PWR-IE170W-PC-AC

PWR-IE240W-PCAC-L

Output Power

50W

170W

240W

Output Voltage / Current

24VDC, 2.1A

54VDC, 3.2A

54VDC, 4.5A

Input Voltage Range

AC 90–264V / DC 106–300V

AC 90–264V / DC 106–300V

AC 90–264V

Input Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Typical Efficiency

80%

88%

91%

Holdup Time (100% Load)

20 ms

20 ms

20 ms

Protection Features

OVP, OCP, OTP, SCP

OVP, OCP, OTP, SCP

OVP, OCP, OTP, SCP

Operating Temperature

-40°C to +75°C

-40°C to +75°C

-40°C to +80°C

Storage Temperature

-40°C to +85°C

-40°C to +85°C

-40°C to +85°C

Humidity

<95% RH (non-condensing)

<95% RH (non-condensing)

5–95% RH (non-condensing)

MTBF (Telcordia SR-332)

1,662,359 hrs

2,384,975 hrs

1,579,900 hrs

Dimensions (W × H × D)

51 × 118 × 148 mm

96 × 150 × 146 mm

85 × 121 × 124.1 mm

Weight

0.64 kg

1.76 kg

0.96 kg

Mounting

DIN-rail

DIN-rail

DIN-rail

Compliance

EN/IEC 60950-1, EN/IEC 62368-1, CE, FCC Part 15B

EN/IEC 60950-1, IEC 61850-3, IEEE 1613, CE, FCC Part 15B

EN/IEC 60950-1, EN/IEC 62368-1, CE, FCC Part 15B

Compatible Devices Table

Cisco Series / Model

Compatible

Notes

Catalyst IE3100 Rugged Series (IE-3100-4T2S-E, IE-3100-8T2C-E, IE-3100-18T2C-E, etc.)

Yes

Officially listed power option. Suitable for deployments without high PoE load.

Catalyst IE3200 Rugged Series

Yes

Works for standard Layer 2/3 switching use cases; not recommended for high PoE demand.

Catalyst IE3300 Rugged Series

Yes

Compatible for low-power environments. For PoE-heavy setups, a higher-wattage PSU is advised.

Catalyst IE3400 Rugged Series

Yes (limited)

Can be used, but PoE or UPoE scenarios require 170W or 240W supplies.

Catalyst IE2000 / IE2000U Series

Yes

Supported on low-power models, typically for compact access applications.

Cisco IR1101 Industrial Router

Yes

Fully compatible; 50W output is sufficient.

Cisco Industrial Gateways (IoT Edge series)

Yes

Ideal for IoT devices and edge connectivity with modest power requirements.

Cisco Industrial Compute (Edge devices)

Conditional

Suitable only for compute units consuming less than 50W; check load requirements.

Specifications

Parameter Specification Parameter Specification
Model PWR-IE50W-AC Product type Industrial DIN-rail AC to DC power supply
Nominal output power 50W Nominal output voltage / current 24VDC, 2.1A
Output adjustment range Fixed 24VDC (see -L variant for 24–28V adj.) Holdup time @100% load 20 ms
Protections Over Voltage, Over Current, Over Temperature, Short Circuit Cooling Fanless, natural convection
Rated nominal input AC 100–240V/1.25A, 50–60Hz or DC 125–250V/1.25A Supported input range AC 90–264V or DC 106–300V
Input frequency 50/60 Hz Typical efficiency 80%
Inrush current (25°C) < 35A @115VAC, < 70A @230VAC Power factor
Operating temperature -40°C to +75°C (no derating) Storage temperature -40°C to +85°C
Operating humidity <95% RH (non-condensing) IP rating IP20
Safety / EMC EN/IEC 60950-1, EN/IEC 62368-1, EN 60079-0/-15, CE, FCC Part 15B Hazardous locations Approved for Class I, Div 2 / Zone 2
Dimensions (W × H × D) 51 × 118 × 148 mm (2.0 × 4.64 × 5.82 in) Weight 0.64 kg (1.41 lb)
MTBF (Telcordia SR-332) 1,662,359 hours Mounting DIN-rail
Compliance notes Industrial EMC standards, CISPR 32/35; see datasheet for full list Warranty Five-year limited hardware warranty

Get More Information

Discover unbeatable prices and fast shipping for the PWR-IE50W-AC Access the detailed PWR-IE50W-AC datasheet and ensure you’re getting the best deal with our reliable delivery service. Need assistance? Our free live chat support is here to help. For more information about the product and pricing, contact us via Live chat or email us at [email protected]

Quality Certifications

Customer Reviews

Write A Review
5.0
(3 reviews)
5 Stars
3
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0
    Maintenance
    Posted on 10/11/2024
    Verified Buyer
    5.0

    Replaced a failed unit. Quick shipping got us back online.

    R2-D2
    Posted on 15/07/2024
    Verified Buyer
    5.0

    (Beep boop whistle) – Power good! Voltage stable!

    Industrial Automation
    Posted on 05/03/2024
    Verified Buyer
    5.0

    Standard DIN rail power supply for our IE3000s. Works as expected.

Questions & Answers

  • What is Cisco PWR-IE50W-AC used for?

    A 50 W industrial AC power supply providing regulated DC output for ruggedized switches and IoT gateways. It’s compact, DIN-rail mountable, and designed for reliable operation in harsh environments.
  • What input and output specs matter most?

    Confirm wide-range 100–240 VAC input and the DC output voltage/current required by your device. Review inrush and hold-up time, especially with UPS or generator feeds.
  • PWR-IE50W-AC vs PWR-IE65W-PC-AC—how to choose?

    Choose 50 W for small loads; choose 65 W when you need extra headroom or plan device additions. Both are industrial-rated and DIN-rail friendly.
  • Does it support protections?

    Yes. Over-current, short-circuit, and over-temperature protections are standard. Investigate downstream wiring if protections trip frequently.
  • Is it suitable for extended temperatures?

    Yes. It’s rated for industrial temperature ranges. Apply derating when ambient rises; ensure adequate ventilation and spacing.
  • How to wire safely?

    Use ferruled conductors, correct polarity, proper grounding, and strain relief. Label AC/L/N and DC +/– for quick service checks.
  • What about EMC and surge immunity?

    Industrial PSUs include EMC filtering and surge handling suitable for noisy cabinets near motors. Additional suppression may be used for extreme events.
  • Typical applications?

    Small IE switches, IoT gateways, serial servers, and protocol converters in automation cabinets.
  • How to calculate margin?

    Sum steady-state power and startup surges, then add 20–30% reserve. Consider future growth to avoid premature upgrades.
  • Maintenance checklist?

    Tighten terminals, dust the cabinet, verify output at load, and replace aging units on a planned cycle.

Warranty

Standard Services

Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.

  • Projects and Technical Support
  • Easy Purchasing Supply
  • Product Lifecycle Protection
  • Exclusive F3 Team Support

Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.

Shipping

Resources Downloads

  • PWR-IE50W-AC Datasheet

Product Tag