PWR-IE50W-AC – 50W AC/DC PSU – 24VDC Output – DIN-Rail

  • 100% Genuine
    Brand-new Cisco hardware
  • SN Verifiable
    Verify before shipment
    -> Check SN
  • 3-Year Warranty
    Extended, enterprise-grade
(6 customer reviews)
Questions

0/mo Solds

List Price: $1,055.24 81% OFF
$197.60
Related Condition
Quantity
Trusted & Secure Payments
Shipping Express Shipping 2-6 Business Days, via UPS, FedEx, DHL and more

Stable Global Supply Chain for Thriving Businesses.

  • $8,000,000 Inventory
  • Certified Cisco Partner ships
  • Collaborating with FedEx, UPS, DHL

Free Expert Support from Planning to Deployment

  • Assistance with product selection and network solution design
  • Configuration guidance and best-practice recommendations
  • Troubleshooting support provided by CCIE-level technical experts

Established Global IT Distributor

With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.

PWR-IE50W-AC Description

PWR-IE50W-AC is a Cisco Industrial DIN-Rail 50W hardwired power supply for rugged Ethernet and industrial access deployments that need 24VDC output from AC or high-voltage DC input. It is listed by Cisco as PWR-IE50W-AC=, supports AC 90-264V or DC 106-300V input, delivers 24VDC at 2.1A with a 50W maximum output, and is a no-PoE supply option used with Cisco industrial platforms such as IE 1000, IE 2000, IE 2000U, and IR809 power-adapter contexts.

Quick Specs

Parameter

Specification

Product ID

PWR-IE50W-AC

Cisco ordering part

PWR-IE50W-AC=

Product type

50W AC-to-DC or high-DC-to-DC power supply

Input connection type

Hardwired

PoE support

No

Rated nominal input

AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A

Supported input range

AC 90-264V or DC 106-300V

Output rating

24VDC, 2.1A

Maximum output power

50W

Holdup time

20ms at 100% load

Operating temperature

-40C to +75C

IP rating

IP20

Application Scenarios

Industrial non-PoE switch power

PWR-IE50W-AC fits Cisco industrial access builds that need a 50W no-PoE DIN-rail supply with 24VDC output rather than the 54VDC PoE supply family.

IE 1000 and IE 2000 power-supply replacement

Cisco IE 1000 and IE 2000 data sheets list PWR-IE50W-AC= as a 50W power-supply option with no PoE or PoE+ support, so replacement orders should not treat it as a powered-device budget source.

Rugged gateway AC adapter sourcing

Cisco IR809 hardware documentation identifies PWR-IE50W-AC as the optional AC power adapter for sites that need 110/220V AC or 88-300V DC input rather than direct low-voltage DC wiring to the router.

Product Comparison

Parameter

PWR-IE50W-AC

PWR-IE65W-PC-AC

PWR-IE50W-AC-IEC

Cisco ordering part

PWR-IE50W-AC=

PWR-IE65W-PC-AC=

PWR-IE50W-AC-IEC=

Product type

50W AC-to-DC or high-DC-to-DC power supply

65W AC-to-DC or high-DC-to-DC PoE power supply

50W AC-to-DC power supply with IEC connector

Input connection type

Hardwired

Hardwired

Plug-in

Rated nominal input

AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A

AC 100-240V/1.4A, 50-60Hz or DC 125-250V/1.0A

AC 100-240V/1.25A, 50-60Hz

Supported input range

AC 90-264V or DC 106-300V

AC 90-264V or DC 106-300V

AC 90-264V

Output rating

24VDC, 2.1A

54VDC, 1.2A

24VDC, 2.1A

Maximum output power

50W

65W

50W

Holdup time at 100% load

20ms

10ms

20ms

Typical efficiency

80%

85%

80%

PoE support

No

Yes

No

IP rating

IP20

IP20

IP20

Hazardous-location approval

Class 1 Div 2 or Zone 2

Class 1 Div 2 or Zone 2

Not approved

Operating temperature

-40C to +75C

-40C to +75C

-20C to +70C

Unit weight

1.41 lb (0.64 kg)

2.64 lb (1.2 kg)

1.43 lb (0.65 kg)

  • In a PWR-IE50W-AC vs PWR-IE50W-AC-L comparison, both are hardwired 50W no-PoE DIN-rail supplies, but PWR-IE50W-AC accepts AC or high-voltage DC input and carries Class 1 Div 2 or Zone 2 approval.
  • The PWR-IE50W-AC difference from PWR-IE50W-AC-IEC is the input connector and input profile: PWR-IE50W-AC is hardwired and supports AC or high-DC input, while the IEC model is plug-in and AC-only.
  • For a PWR-IE50W-AC vs PWR-IE65W-PC-AC comparison, the key difference is output role. PWR-IE50W-AC provides 24VDC no-PoE output, while PWR-IE65W-PC-AC provides 54VDC output with PoE support.
  • Buyers comparing which model to choose should verify hardwired versus plug-in input, 24VDC versus 54VDC output, PoE requirement, and hazardous-location approval in the comparison table.

Selection Guide

1. Select the 24VDC no-PoE supply profile

Select PWR-IE50W-AC when the Cisco industrial device requires a 50W hardwired supply with 24VDC output and no PoE power budget.

2. Separate IEC plug-in installations early

Move the order to PWR-IE50W-AC-IEC only when the installation expects the IEC C14 plug-in connector instead of terminal-block source wiring.

3. Do not substitute it for PoE loads

Use PWR-IE65W-PC-AC or another Cisco-documented PoE supply when the BOM requires 54VDC PoE output rather than the 24VDC output on PWR-IE50W-AC.

4. Check industrial approval and platform context

Review Class 1 Div 2 or Zone 2 requirements, IP20 enclosure assumptions, and the Cisco platform document that lists the supply before releasing the quote.

Ordering Checklist

Check Area

Evidence to Confirm

Risk Controlled

PID format

Base PID PWR-IE50W-AC and Cisco ordering part PWR-IE50W-AC=

Keeps the catalog record aligned with Cisco spare notation

Input source

AC 100-240V/1.25A at 50-60Hz or DC 125-250V/1.25A

Avoids ordering an AC-only 50W variant for a high-DC cabinet

Output requirement

24VDC at 2.1A with 50W maximum output

Prevents a 54VDC PoE supply or higher-wattage line from being substituted by habit

Connection method

Hardwired DIN-rail input connection

Avoids expecting an IEC plug-in power cord on the base SKU

Environmental fit

IP20, -40C to +75C operating temperature, and no derating

Matches the supply to enclosure and cabinet temperature assumptions

Approval boundary

Class 1 Div 2 or Zone 2 approval listed for PWR-IE50W-AC=

Keeps the order separate from 50W variants not approved for hazardous locations

Platform context

Cisco IE 1000, IE 2000, IE 2000U, and IR809 documentation list this 50W supply in defined power contexts

Prevents treating it as a generic DIN-rail converter

Specifications

Parameter Specification Parameter Specification
Product ID PWR-IE50W-AC Cisco ordering part PWR-IE50W-AC=
Product type 50W AC-to-DC or high-DC-to-DC power supply Ordering description 50W AC to DC power supply
Input connection type Hardwired PoE support No
Rated nominal input AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A Supported input range AC 90-264V or DC 106-300V
Typical efficiency 80% Inrush current <35A at 115VAC and 70A at 230VAC
Output rating 24VDC, 2.1A Maximum output power 50W
Holdup time at 100% load 20ms IP rating IP20
Operating temperature -40C to +75C Storage temperature -40C to +85C
Power derating No derating Operating humidity <95% RH, non-condensing
Dimensions 51 x 118 x 148 mm; 2 x 4.64 x 5.82 in. Unit weight 1.41 lb (0.64 kg)
MTBF 1,662,359 hours Hazardous-location entry Class 1 Div 2 or Zone 2
Safety entries EN60950-1, EN62368-1, IEC60950-1, IEC62368-1, EN60079-0, EN60079-15, CE EMC entries EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN61000-4-11, IEC61000-4-11, IEC61000-4-12, IEC61000-4-16, CISPR 32, EN 55032, CISPR35, EN55035, FCC 47 CFR Part 15B
IE 2000U context Listed as a 50W DC- or AC-input power supply module for IE 2000U    

Get More Information

Need pricing, stock, or shipping details for the PWR-IE50W-AC ? Layer23-Switch can help you check current availability, lead time, and delivery options for this. Send us the part number, quantity, and destination country via live chat or email sales@layer23-switch.com for a fast quotation.

Quality Certifications

Customer Reviews

Write A Review
5.0
(6 reviews)
5 Stars
6
4 Stars
0
3 Stars
0
2 Stars
0
1 Stars
0
    Terry Zhang
    Posted on 16/03/2026
    Verified Buyer
    5.0

    Our risk assessment ranked Layer23 as low-risk, high-confidence.

    Mark Hall
    Posted on 01/01/2026
    Verified Buyer
    5.0

    Pricing was attractive enough that we placed a larger order than planned.

    Michelle Sato
    Posted on 26/12/2025
    Verified Buyer
    5.0

    Product works, seller is honest, price is fair. What more do you want?

    Maintenance
    Posted on 10/11/2024
    Verified Buyer
    5.0

    Replaced a failed unit. Quick shipping got us back online.

    R2-D2
    Posted on 15/07/2024
    Verified Buyer
    5.0

    (Beep boop whistle) – Power good! Voltage stable!

Questions & Answers

  • Which 50W hazardous cabinet uses PWR-IE50W-AC?

    PWR-IE50W-AC fits low-power Cisco industrial Ethernet devices needing a 50W DIN-rail supply with hazardous approval and dual AC or high-voltage DC input.
  • Which input flexibility matters for PWR-IE50W-AC?

    PWR-IE50W-AC accepts broad AC input and high-voltage DC input, giving industrial panels flexibility when the site power source is not standard office AC.
  • Which HazLoc difference separates PWR-IE50W-AC?

    PWR-IE50W-AC carries Class 1 Div 2 and Zone 2 approval, while PWR-IE50W-AC-L is the non-hazardous-location 50W variant for this exact cabinet design.
  • Which output planning applies to PWR-IE50W-AC?

    PWR-IE50W-AC is used for 50W industrial device power, so switch load, accessories, and redundancy plans need total wattage review.
  • Can PWR-IE50W-AC cover industrial PoE power?

    PWR-IE50W-AC is sized for low-power industrial devices, not PoE-heavy switches; higher-wattage models cover powered field endpoints for this exact cabinet design.
  • Why do control-panel installers ask about PWR-IE50W-AC?

    PWR-IE50W-AC questions often involve DIN-rail mounting, hazardous-area approval, input wiring, temperature range, and matching the exact IE switch load.
  • Which redundancy detail matters for PWR-IE50W-AC?

    PWR-IE50W-AC redundancy planning checks whether the powered industrial switch has dual DC inputs and whether two supplies are wired separately.
  • Which cabinet requirement rules out PWR-IE50W-AC?

    PWR-IE50W-AC is a mismatch when the project needs IEC cord input, higher PoE output, or a low-voltage DC-only power source.

Warranty

Visit How to Pay page for more information

EOL EOSL checker
Check lifecycle dates
FREE NETWORK TOOLS

Verify, plan, and comparewith confidence

Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.

Standard Services

Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.

  • Projects and Technical Support
  • Easy Purchasing Supply
  • Product Lifecycle Protection
  • Exclusive F3 Team Support

Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.

Shipping

DataSheet Downloads

  • PWR-IE50W-AC Datasheet