PWR-CC1-400WAC – 400W AC PSU – Catalyst 8300 1RU uCPE

  • 100% Genuine
    Brand-new Cisco hardware
  • SN Verifiable
    Verify before shipment
    -> Check SN
  • 3-Year Warranty
    Extended, enterprise-grade
(7 customer reviews)
Questions

0/mo Solds

List Price: $6,248.00 88% OFF
$781.00
Related Condition
Quantity
Trusted & Secure Payments
Shipping Express Shipping 2-6 Business Days, via UPS, FedEx, DHL and more

Stable Global Supply Chain for Thriving Businesses.

  • $8,000,000 Inventory
  • Certified Cisco Partner ships
  • Collaborating with FedEx, UPS, DHL

Free Expert Support from Planning to Deployment

  • Assistance with product selection and network solution design
  • Configuration guidance and best-practice recommendations
  • Troubleshooting support provided by CCIE-level technical experts

Established Global IT Distributor

With over a decade of industry experience, we are a certified Cisco Partner delivering genuine enterprise networking hardware and trusted services to system integrators, ISPs, and enterprises worldwide.

PWR-CC1-400WAC Description

PWR-CC1-400WAC is a Cisco Catalyst 8300 Series 400W AC power supply for Catalyst 8300 Edge uCPE deployments, with C8300-UCPE-1N20 listed by Cisco as its primary 1RU platform context. It is an AC PSU and spare-orderable part, with Cisco listing PWR-CC1-400WAC= as the spare PID, 100 to 240 VAC at 50 to 60 Hz input, 80 Plus Silver efficiency, 12V 33A output, 20 ms holdup time, and an IEC 320 C14 input receptacle for AC power-cable matching.

Quick Specs

Parameter

Specification

Product ID

PWR-CC1-400WAC

Product type

AC power supply

Primary compatible platform

C8300-UCPE-1N20

uCPE platform role

Catalyst 8300 1RU AC power supply

Power maximum rating

400W

Input voltage and frequency

100 to 240 VAC, 50 to 60 Hz

Power supply efficiency

80 Plus Silver

Input current

6A to 3A

Output rating

12V, 33A

Output holdup time

20 ms

Input receptacle

IEC 320 C14

Application Scenarios

Catalyst 8300 uCPE AC power replacement

PWR-CC1-400WAC fits C8300-UCPE-1N20 deployments that are standardized on AC facility power and need a Cisco-listed 400W PSU or spare.

AC and DC service-stock separation

Operations teams can keep PWR-CC1-400WAC for AC-fed C8300-UCPE-1N20 sites and reserve PWR-CC1-400WDC for DC plant locations that use terminal-block input.

Legacy 1RU edge-platform PSU clarification

For non-uCPE Catalyst 8300 1RU edge platforms, this PID should be checked against Cisco’s temporary substitute notice rather than treated as the current default 250W AC supply line.

Product Comparison

Parameter

PWR-CC1-400WAC

PWR-CC1-400WDC

PWR-CC1-250WAC

Product type

AC power supply

DC power supply

AC power supply

Documented platform context

C8300-UCPE-1N20 and legacy 1RU substitute notice

C8300-UCPE-1N20 and Catalyst 8300 1RU DC power option

C8300-1N1S-4T2X and C8300-1N1S-6T

Spare part number

PWR-CC1-400WAC=

PWR-CC1-400WDC=

PWR-CC1-250WAC=

Power maximum rating

400W in uCPE power-supply specifications

400W

250W

Input voltage and frequency

100 to 240 VAC, 50 to 60 Hz

-40 to -72 VDC

100 to 240 VAC, 50 to 60 Hz

Power supply efficiency

80 Plus Silver

85 percent

80 Plus Silver

Input current

6A to 3A

13A to 7.25A

3A to 1.25A

Output rating

12V, 33A

12V, 33.5A

12V, 21A

Output holdup time

20 ms

2 ms

20 ms

Input receptacle

IEC 320 C14

Terminal block

IEC 320 C14

Power cord rating

10A

15A #14 wire

5A

  • In a PWR-CC1-400WAC vs PWR-CC1-400WDC comparison, the main difference is input power: PWR-CC1-400WAC uses 100 to 240 VAC with an IEC 320 C14 receptacle, while PWR-CC1-400WDC uses -40 to -72 VDC with a terminal block.
  • The PWR-CC1-400WAC difference from PWR-CC1-250WAC is platform context and rating. PWR-CC1-400WAC is listed as the 400W AC PSU for C8300-UCPE-1N20, while PWR-CC1-250WAC is the 250W AC supply for C8300-1N1S-4T2X and C8300-1N1S-6T.
  • For buyers comparing which model to choose, the comparison should separate C8300-UCPE-1N20 service order, 1RU edge-platform 250W AC replacement, and DC input requirements before the order line is released.

Selection Guide

1. Start with the platform family

Choose PWR-CC1-400WAC for C8300-UCPE-1N20 AC power-supply requirements.

2. Do not mix AC and DC PSU orders

Select PWR-CC1-400WDC instead when the C8300-UCPE-1N20 deployment is wired for -40 to -72 VDC input.

3. Keep the 250W edge-platform line separate

For C8300-1N1S-4T2X or C8300-1N1S-6T default AC replacement, verify whether the order should remain on PWR-CC1-250WAC or references Cisco’s older temporary substitute notice.

4. Confirm spare-part formatting

Use PWR-CC1-400WAC= when procurement needs the Cisco spare PSU part number rather than the base power-supply PID.

Ordering Checklist

Control Point

Required Evidence

Ordering Risk

Exact power supply ID

PWR-CC1-400WAC or spare PWR-CC1-400WAC=

Prevents a DC PSU or 250W AC PSU from being placed on the same replacement order

AC input feed

100 to 240 VAC, 50 to 60 Hz

Matches the Cisco-listed input range for this AC supply

Output class

400W, 12V, 33A

Separates the uCPE 400W PSU from the 250W AC supply used on C8300-1N1S models

Power cord

IEC 320 C14 receptacle with 10A regional cord rating

Keeps the rack power cable aligned with the Cisco-listed receptacle and cord rating

Redundancy plan

C8300-UCPE-1N20 ships with two power supplies for redundancy

Determines whether the order is a single spare replacement or part of a matched redundant pair

Substitute boundary

Cisco states PWR-CC1-400WAC is no longer shipped with current Catalyst 8300 1RU edge platforms

Prevents a legacy supply-chain substitution from being misread as the normal 1RU edge-platform default

Specifications

Parameter Specification Parameter Specification
Product ID PWR-CC1-400WAC Spare part number PWR-CC1-400WAC=
Product type AC power supply Primary compatible platform C8300-UCPE-1N20
uCPE platform role Catalyst 8300 1RU AC power supply Power maximum rating 400W
Input voltage and frequency 100 to 240 VAC, 50 to 60 Hz Power supply efficiency 80 Plus Silver
Input current 6A to 3A Output rating 12V, 33A
Output holdup time 20 ms Input receptacle IEC 320 C14
Power cord rating 10A uCPE default power design Two power supplies for redundancy
DC alternative PWR-CC1-400WDC, 400W DC supply Legacy 1RU substitute note Temporary substitute for PWR-CC1-250WAC with same support
Current 1RU edge-platform note No longer shipped with current Catalyst 8300 1RU edge platforms Country power cable note Power cables must be chosen by deployment country

Get More Information

Need pricing, stock, or shipping details for the PWR-CC1-400WAC ? Layer23-Switch can help you check current availability, lead time, and delivery options for this. Send us the part number, quantity, and destination country via live chat or email sales@layer23-switch.com for a fast quotation.

Quality Certifications

Customer Reviews

Write A Review
4.7
(7 reviews)
5 Stars
5
4 Stars
2
3 Stars
0
2 Stars
0
1 Stars
0
    Lawrence Warren
    Posted on 24/01/2026
    Verified Buyer
    4.0

    Their reputation is well-deserved. Everything went as expected.

    Larry Ruiz
    Posted on 06/01/2026
    Verified Buyer
    5.0

    Our experience aligns with the positive reviews. No marketing hype here.

    Susan Cook
    Posted on 19/12/2025
    Verified Buyer
    4.0

    Layer23’s pricing is competitive without sacrificing product quality. That’s rare. Wish the lead time was a bit shorter, but product quality made up for it.

    Procurement
    Posted on 10/10/2024
    Verified Buyer
    5.0

    Invoice provided promptly. Smooth transaction.

    Matt Murdock
    Posted on 15/06/2024
    Verified Buyer
    5.0

    I can sense the quality of the service. Very good.

Questions & Answers

  • Which Catalyst 8300 AC design uses PWR-CC1-400WAC?

    PWR-CC1-400WAC fits Catalyst 8300 1RU edge platforms installed in branch cabinets with standard AC feed and no router PoE requirement.
  • What input specification matters for PWR-CC1-400WAC?

    PWR-CC1-400WAC uses 100 to 240 VAC input at 50 to 60 Hz, with an IEC C14 inlet and 10A cord planning.
  • Which AC versus DC choice separates PWR-CC1-400WAC?

    PWR-CC1-400WAC is chosen for AC cabinets using IEC power cords; the DC version targets telecom power plants and terminal-block wiring.
  • Which AC output profile defines PWR-CC1-400WAC?

    PWR-CC1-400WAC delivers 12V system power at roughly 33A, so it is evaluated as an AC router PSU rather than a PoE supply.
  • Can the 400W AC unit replace PWR-CC1-250WAC?

    PWR-CC1-400WAC may appear as a higher-capacity AC option, but replacement planning still follows Catalyst 8300 PSU support tables.
  • Which rack-planning detail matters for PWR-CC1-400WAC?

    PWR-CC1-400WAC rack planning checks AC feed availability, cable type, PSU slot population, and heat load in the branch cabinet.
  • Why do ordering pages compare PWR-CC1-400WAC and 500WAC?

    PWR-CC1-400WAC is compared with 500WAC because the 500W version adds PoE output capacity for endpoint-powered branch designs today.
  • Which DC or PoE design rules out PWR-CC1-400WAC?

    PWR-CC1-400WAC is a mismatch for DC-powered telecom rooms or branch routers that need chassis PoE output for endpoints.

Warranty

Visit How to Pay page for more information

EOL EOSL checker
Check lifecycle dates
FREE NETWORK TOOLS

Verify, plan, and comparewith confidence

Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.

Standard Services

Personalized Service, Superior Product Maintenance for Ultimate Satisfaction.

  • Projects and Technical Support
  • Easy Purchasing Supply
  • Product Lifecycle Protection
  • Exclusive F3 Team Support

Customized Support for Your Needs with CCIE, HCIE, HPE ASE, etc.

Shipping

DataSheet Downloads

  • PWR-CC1-400WAC Datasheet