IE-9320-26S2C-E – 22x GE SFP + 2x Combo Downlinks – 4x GE SFP Uplinks – Stackable, Network Essentials

Cisco SN CheckSN verification before shipment.Verify authenticity3-Year WarrantyExtended, enterprise-gradeWarranty terms14-Day ReturnsStraightforward RMA processReturn policy
4.926 reviews7 Questions3 sold this month
List Price: $13,309.74 48% OFF
$6,939.00
Price Alert
Condition
Related
Quantity
Shipping Express Shipping 2-6 Business Days, via UPS, FedEx, DHL and more
Trusted & Secure Payments

Shop Expert-Recommended Accessories for the IE-9320-26S2C-E

Explore optics, stacking accessories, modules, and power supplies—all verified by our engineers for use with this model.
  • GLC-LH-SMD

    GLC-LH-SMD

    1000BASE-LX/LH SFP - 10km SMF / 550m MMF - DOM
    Original price was: $1,260.58.Current price is: $95.80.
  • GLC-TE

    GLC-TE

    1000BASE-T SFP - RJ-45 Cat5 Copper - 100m Reach
    Original price was: $570.10.Current price is: $70.00.
  • GLC-SX-MMD

    GLC-SX-MMD

    1000BASE-SX SFP - MMF 850nm - DOM
    Original price was: $633.46.Current price is: $59.00.
  • GLC-EX-SMD

    GLC-EX-SMD

    1000BASE-EX SFP - 40km SMF - DOM
    Original price was: $2,527.49.Current price is: $205.00.
  • GLC-ZX-SMD

    GLC-ZX-SMD

    1000BASE-ZX SFP - 70km SMF - EXT DOM
    Original price was: $5,061.30.Current price is: $215.70.
  • PWR-RGD-AC-DC-H

    PWR-RGD-AC-DC-H

    150W AC/DC PSU - Cisco IE4010/IE5000/IE9300/IR8340
    Original price was: $853.95.Current price is: $710.00.
  • PWR-RGD-LOW-DC-H

    PWR-RGD-LOW-DC-H

    150W Low DC Power Supply - Hazardous Locations - PoE/PoE+
    Original price was: $886.83.Current price is: $780.00.

Why Layer23-Switch

Stocked, Shipped and Supported by One Team

Founded
Customers
Units shipped
Countries

Inventory You Can See

Cisco stock on hand
Models ready to ship
Warehouse space

Ships in 1 Business Day

In-stock orders leave our Hong Kong or U.S. warehouse within 1 business day after payment, with tracking by email.

DHL FedEx UPS Duties included: US · CA · UK

LSCare Warranty

3years on enterprise equipment

  • Advance replacement for in-stock models
  • New unit for dead-on-arrival
  • 14-day returns on sealed items

Free CCIE Support

Certified engineers help before and after you buy. Reply within 1 business day by email or live chat.

Part number check Configuration Troubleshooting

Verify Before You Pay

100%factory-sealed

Get label and serial photos before shipment, and check every serial number with Cisco.

IE-9320-26S2C-E Description

The IE-9320-26S2C-E is a Cisco Catalyst IE9300 Rugged Series stackable industrial switch for fiber aggregation in substation and roadside cabinets. The fanless 1RU rack-mount switch has 22 Gigabit SFP downlinks, 2 dual-media downlinks and 4 Gigabit SFP uplinks, and it operates from -40°C to +75°C in a forced-air cabinet. The switch has no PoE, and BGP, EIGRP, VRF-lite and TrustSec need Network Advantage rather than the Network Essentials license it carries.

Quick Specs

Parameter

Specification

Product ID

IE-9320-26S2C-E

Downlink ports

22x 100/1000M SFP + 2x dual-media (SFP or RJ45)

Uplink ports

4x 100/1000M SFP

Network license

Network Essentials (upgradeable via IE9300-NW-A=)

Stacking

Cisco StackWise, 2 stack ports, up to 4 members

Forwarding rate

41.66 Mpps

Routing at Essentials

Static, OSPF (1,000 routes), OSPFv3, RIP, PBR

Seamless redundancy

HSR, PRP, PTP over PRP (supported on this model)

Power modules

2x modular slots; 150W/250W/400W AC-DC and 150W low-voltage DC options

Power consumption

64W (indicative)

Operating temperature

-40°C to +75°C (forced-air cabinet); -40°C to +60°C sealed

Alarm and console

4 alarm in / 1 Form-C alarm out; RJ-45 + Micro USB console

Mounting

1RU rack mount, fanless, IP30

Product Performance

SFP-Dominated Interface Count
OSPF Capacity In The Base License
MAC Table From IOS XE 17.17.1

Key Features

Routing Without An Upgrade

Static routing, OSPF with 1,000 routes, OSPFv3, RIP and policy-based routing all come with the base license. A fiber aggregation node can run a routed design on day one, and BGP, EIGRP and VRF-lite wait for Network Advantage.

HSR And PRP Seamless Redundancy

This 26S2C model supports HSR, PRP and PTP over PRP at the Essentials tier. Protection and control traffic rides duplicated LANs with zero recovery time.

Rings That Span The Stack

Two StackWise ports join up to four chassis. MRP over Stacking then lets a media redundancy ring enter and leave on different stack members, so the aggregation point itself survives a chassis failure.

Dual Modular Power

Two field-replaceable, electrically isolated power slots take 150W, 250W or 400W AC/DC modules, or a 150W low-voltage DC module for 18-75V feeds. The switch has no PoE, so the second module adds supply redundancy only.

Wide Temperature And Hazardous Locations

The fanless chassis runs from -40°C to +75°C in a forced-air cabinet and to +60°C in a sealed one. Class I Division 2 and Zone 2 listings cover installation in hazardous-location cabinets.

Utility, ITS And Rail Compliance

IEC 61850-3, IEEE 1613 and the IEC 61850-9-3 Power Utility Profile cover substations. NEMA TS2 covers roadside cabinets, and EN 50121-4 and AREMA 2019 cover trackside installations.

Application Scenarios

Substation Protection LAN

In a substation control house, the switch serves as the PRP connection point for protection relays and merging units, using HSR and PRP for duplicated lossless LANs and IEC 61850-9-3 Power Utility Profile timing.

Municipal Fiber Aggregation

A city collecting traffic-signal and camera cabinets over single-mode fiber can run OSPF and REP rings on the switch, then add stack members as more cabinets come online.

Pump Station SCADA Hub

Water and energy sites with hazardous-location cabinets can concentrate SCADA and GOOSE traffic on the switch, which has dual isolated power modules and rated operation to +75°C in a forced-air cabinet.

Product Comparison

Parameter

IE-9320-26S2C-E

IE-9320-26S2C-A

IE-9310-26S2C-E

Downlink ports

22x 100/1000M SFP + 2x dual-media

22x 100/1000M SFP + 2x dual-media

22x 100/1000M SFP + 2x dual-media

Uplink ports

4x 100/1000M SFP

4x 100/1000M SFP

4x 100/1000M SFP

Stacking

StackWise, up to 4 members

StackWise, up to 4 members

Not stackable

Ring redundancy protocols

REP, MRP, MRP over Stacking, HSR, PRP

REP, MRP, MRP over Stacking, HSR, PRP

REP, MRP

Power modules

2 slots: 150W, 250W, 400W AC/DC or 150W low-voltage DC

2 slots: 150W, 250W, 400W AC/DC or 150W low-voltage DC

2 slots: 150W, 250W, 400W AC/DC or 150W low-voltage DC

Power consumption

64W

64W

61W

Operating temperature

-40°C to +75°C (forced-air cabinet)

-40°C to +75°C (forced-air cabinet)

-40°C to +75°C (forced-air cabinet)

Mounting

1RU rack mount

1RU rack mount

1RU rack mount

Network license

Network Essentials

Network Advantage: adds BGP, EIGRP, VRF-lite, TrustSec, MACsec-256

Network Essentials

IE-9320-26S2C-E and IE-9310-26S2C-E share the same 22 SFP and 2 combo downlinks, 4 SFP uplinks and Network Essentials license, but IE-9320-26S2C-E adds Cisco StackWise with up to 4 members and MRP over Stacking, while IE-9310-26S2C-E is not stackable. A fiber site that will outgrow 28 ports, or needs a media redundancy ring that survives a chassis failure, stays on IE-9320-26S2C-E; a permanently single-chassis site can take IE-9310-26S2C-E, which draws 61W against 64W. When day-one BGP, EIGRP, VRF-lite, TrustSec or MACsec-256 is needed, order IE-9320-26S2C-A, which carries the same stackable hardware with Network Advantage; an installed IE-9320-26S2C-E can move to it later with the perpetual IE9300-NW-A= upgrade license.

Ordering Checklist

  • Power modules: Choose per slot from PWR-RGD-LOW-DC-H (150W, 18-75V DC), PWR-RGD-AC-DC-H (150W), PWR-RGD-AC-DC-250 or PWR-RGD-AC-DC-400, matched to the cabinet feed. The power modules are separate PIDs, and on this non-PoE model the second module provides supply redundancy.
  • Catalyst Center license: Add an optional IE9300-DNA-E term (3, 5 or 7 years) if Catalyst Center manages the switch. The license is a separate add-on, and the Advantage variant IE9300-DNA-A pairs only with Network Advantage switches.
  • Industrial SFPs: Order industrial-grade optics such as GLC-SX-MM-RGD or -I grade GLC-BX, and keep GLC-TE, GLC-T and GLC-T-RGD off the order. Copper SFPs degrade PTP accuracy and are not supported on the two dual-media combo ports; non-industrial SFPs need temperature derating.
  • SD card: Add SD-IE-16GB= (16 GB) for SwapDrive configuration restore. The SD card is optional and is not in the chassis order by default.
  • Rack kit: Select RM-RGD-19IN=, RM-RGD-23IN= (NEBS) or RM-RGD-ETSI= to match the rack standard. The rack mounting kits are separate PIDs for each standard.
  • Stack cables: Add CAB-STK-0.5M= or CAB-STK-1M= for each member added to the stack, up to 4 members. StackWise and MRP over Stacking run only over these dedicated stack cables.

Optional Add-ons

Model

Description

IE9300-NW-A=

Perpetual Network Advantage upgrade license for -E units

PWR-RGD-AC-DC-H=

150W AC-DC power module, 85-264V AC / 88-300V DC input

PWR-RGD-LOW-DC-H=

150W low-voltage DC power module, 18-75V input range

CAB-STK-0.5M=

StackWise stacking cable, 0.5 m

CAB-STK-1M=

StackWise stacking cable, 1 m

RM-RGD-19IN=

19-inch rack mount kit

SD-IE-16GB=

16GB SD card for configuration and SwapDrive replacement

GLC-SX-MM-RGD=

Industrial-grade 1000BASE-SX SFP

IE-9320-26S2C-E Front Panel Overview

The illustrations in this section provide an overview of the variety of components available on the various switch models in this product family. Not all models are illustrated.

1

Display mode button

6

Alarms

2

Express Setup button

7

RJ-45 console port

3

Ethernet SFP downlinks

8

(Beneath cover) Micro-USB console port, USB-A host port, and SD slot

4

Dual-media downlink ports

9

Stacking interface (IE9320 switches only)

5

Ethernet SFP uplinks

10

AC/DC power input

Specifications

Parameter Specification Parameter Specification
Product ID IE-9320-26S2C-E Network license Network Essentials; perpetual in-place upgrade via IE9300-NW-A=
Downlink ports 22x 100/1000M SFP + 2x dual-media (SFP or 10/100/1000M RJ45) Uplink ports 4x 100/1000M SFP
Stacking Cisco StackWise, 2 stack ports, up to 4 members; MRP over Stacking Performance 41.66 Mpps; 28 Gbps forwarding, 56 Gbps switching bandwidth
Scale (IOS XE 17.17.1+) 24,000 MAC; 4,096 VLAN IDs, 1,024 active VLANs; 128 STP instances; 1,536 ACL entries Memory 4 GB DRAM; 8 GB flash (~2.5 GB user); optional 16 GB SD card
Essentials features Static routing, OSPF (1,000 routes), OSPFv3, RIP, PBR; REP/REP Fast, MRP/Fast MRP, PTP over MRP, HSR, PRP, PTP over PRP; PROFINET, CIP, GOOSE/SCADA classification, L2 NAT, Modbus TCP, ERSPAN, IOx; 802.1X, DAI, DHCP snooping, IPv6 FHS, FNF, MACsec-128, TLS 1.3 Advantage upgrade adds BGP, EIGRP, IS-IS, HSRP, LISP, BGP-EVPN over VXLAN, VRF-lite, TrustSec (SGACL, over PRP), MACsec-256, L3 NAT, multicast routing suite, SD-Access fabric roles, GRE, IP SLA
PTP timing IEEE 1588 PTPv2 Default and Power Profile (2011/2017); IEC 61850-9-3 PUP; NTP-PTP interworking Model boundaries HSR/PRP supported on this 26S2C model at Essentials; GNSS/IRIG-B only on 22S2C4X models; TrustSec over PRP requires -A
Management WebUI, Cisco Catalyst Center, SNMP, NETCONF/RESTCONF/YANG, EEM, PnP, Day-0 ZTP Security hardware IOS XE Secure Boot, image signing, Trust Anchor module; FIPS 140-2
Power modules 2x field-replaceable slots, isolated outputs: PWR-RGD-LOW-DC-H (150W, 18-75V DC), PWR-RGD-AC-DC-H (150W), -250 (250W), -400 (400W) Power consumption 64W (indicative)
Alarms / console 4 dry-contact alarm in, 1 Form-C alarm out; RS-232 RJ-45 + Micro USB console; optional USB 2.0 and SD card Operating temperature -40°C to +75°C forced-air cabinet; +70°C vented; +60°C sealed (safety approval to 60°C)
Altitude / humidity 15,000 ft without derating, to 40,000 ft derated to 25°C; 5-95% non-condensing; storage -40°C to +85°C Dimensions / weight 1.72 x 17.5 x 14.0 in with -H modules; 5.53 kg (12.2 lb) chassis without power modules; 1RU, fanless, IP30
MTBF 492,370 hours Industrial compliance IEC 61850-3, IEEE 1613, IEC 61850-9-3 PUP, NEMA TS2:2021, EN 50121-4, EN 50121-3-2, EN 50125-1/-3, AREMA 2019, IEC 62443-4-1/-4-2, ODVA EtherNet/IP; hazloc Class I Div 2 / Zone 2

Quality Certifications

Customer Reviews

Write A Review
4.9
(26 reviews)
5 Stars
23
4 Stars
3
3 Stars
0
2 Stars
0
1 Stars
0
    Kathryn Wright
    Posted on 20/04/2026
    Verified Buyer
    5.0

    Layer23 stays engaged after the sale. That builds long-term trust.

    Michael Yamamoto
    Posted on 07/04/2026
    Verified Buyer
    5.0

    Sales process was smooth — no unnecessary back-and-forth or confusion.

    Catherine Costa
    Posted on 13/03/2026
    Verified Buyer
    4.0

    Hands-off operation since installation. Reliable performance. Shipping took a couple extra days, but product itself is perfect.

    Jessica Jones
    Posted on 22/08/2025
    Verified Buyer
    5.0

    Quick and painless. Just how I like it.

    Network Eng
    Posted on 12/04/2025
    Verified Buyer
    5.0

    Hard to find item in stock. Glad you had it.

Questions & Answers

  • What is the operating temperature range of IE-9320-26S2C-E?

    IE-9320-26S2C-E operates from -40°C to +75°C in a forced-air cabinet. Vented enclosures are rated to +70°C and sealed enclosures to +60°C, which is the limit of the safety approval. The fanless chassis needs no derating up to 15,000 ft.
  • What input voltage does IE-9320-26S2C-E accept?

    IE-9320-26S2C-E accepts 85-264V AC or 88-300V DC through its AC-DC power modules, and a low-voltage DC module covers DC-only feeds. The switch has no PoE, so a second module adds supply redundancy only, and the two slots have isolated outputs.
  • Can IE-9320-26S2C-E apply TrustSec SGACL policy?

    Not on Network Essentials. TrustSec with SGACL and logging is a Network Advantage feature, so it needs the perpetual IE9300-NW-A= license. The 17.17.1 scale table then allows 2,000 SGT/DGT policies and 10,000 IPv4-SGT bindings.
  • Is Cisco Cyber Vision part of the license on IE-9320-26S2C-E?

    No. The 3-year, 24-endpoint Cyber Vision Advantage license (CV-A-IE) is bundled only with Network Advantage switches ordered on or after 2025-08-23. IE-9320-26S2C-E ships with Network Essentials, so Cyber Vision would be a separate purchase.
  • Which railway standards does IE-9320-26S2C-E meet?

    IE-9320-26S2C-E lists EN 50121-4 and EN 50121-3-2:2016+A1:2019 for railway EMC, EN 50125-1 for the railway environmental conditions of the equipment, and AREMA 2019. These ratings suit trackside and wayside cabinets.
  • Which security and IPv6 certifications does IE-9320-26S2C-E list?

    IE-9320-26S2C-E lists FIPS 140-2, Common Criteria, USGv6-r1 and IPv6 Ready Logo v5, plus IEC/ANSI/ISA-62443-4-1 and 62443-4-2 for industrial cybersecurity. ODVA EtherNet/IP conformance is also listed, which matters for CIP automation networks.
  • Which PID orders a spare 400W power module for IE-9320-26S2C-E?

    Order PWR-RGD-AC-DC-400=, the spare form of the 400W module; the trailing equals sign marks a spare. The 150W low-voltage module PWR-RGD-LOW-DC-H covers 18-75V DC, with 24-60V nominal, and the second slot gives a redundant feed.

Warranty

Visit How to Pay page for more information

FREE NETWORK TOOLS

Verify, plan, and comparewith confidence

Use practical tools to check device details, review lifecyclemilestones, and compare hardware before you buy.

DataSheet Downloads

  • IE-9320-26S2C-E Datasheet